The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Statistical model for diffusion attenuated MR signal
Open accessAbstract
A general statistical model that can describe a rather large number of experimental results related to the structure of the diffusion‐attenuated MR signal in biological systems is introduced. The theoretical framework relies on a phenomenological model that introduces a distribution function for tissue apparent diffusion coefficients (ADC). It is shown that at least two parameters—the position of distribution maxima (ADC) and the distribution width (σ)—are needed to describe the MR signal in most regions of a human brain. A substantial distribution width, on the order of 36% of the ADC, was found for practically all brain regions examined. This method of modeling the MR diffusion measurement allows determination of an intrinsic tissue‐specific ADC for a given diffusion time independent of the strength of diffusion sensitizing gradients. The model accounts for the previously found biexponential behavior of the diffusion‐attenuated MR signal in CNS. Magn Reson Med 50:664–669, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An analytical model of restricted diffusion in bovine optic nerve
Stanisz, G. J., Wright, G. A., Henkelman, R. M., & Szafer, A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370115 · Cited by 501
Cited by
Jensen, J. H., Helpern, J. A., Ramani, A., Lu, H., & Kaczynski, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20508 · Cited by 2,488
MRI quantification of non-gaussian water diffusion by kurtosis analysis
Jensen, J. H., & Helpern, J. A. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1518 · Cited by 1,251
Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581
Clinical intravoxel incoherent motion and diffusion MR imaging: Past, present, and future
Iima, M., & Le Bihan, D. (2016) · Radiology · doi:10.1148/radiol.2015150244 · Cited by 498
Diffusion MRI at 25: exploring brain tissue structure and function
Le Bihan, D., & Johansen-Berg, H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.006 · Cited by 498
Metadata
- Authors
- Yablonskiy, D. A., Bretthorst, G. L., & Ackerman, J. J. H.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2003-09-26
- Volume
- 50
- Issue
- 4
- Pages
- 664-669
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1990711988
- Cited by
- 233
- References
- 1
- FWCI
- 2.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Statistical model for diffusion attenuated MR signal. https://app.cochat.ai/papers/10.1002/mrm.10578
- The paper
- Yablonskiy, D. A., Bretthorst, G. L., & Ackerman, J. J. H. (2003). Statistical model for diffusion attenuated MR signal. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10578
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.