The DOI matches its Crossref record.
Proton HR‐MAS spectroscopy and quantitative pathologic analysis of MRI/3D‐MRSI‐targeted postsurgical prostate tissues
Open accessAbstract
Proton high‐resolution magic angle spinning (1 H HR‐MAS) NMR spectroscopy and quantitative histopathology were performed on the same 54 MRI/3D‐MRSI‐targeted postsurgical prostate tissue samples. Presurgical MRI/3D‐MRSI targeted healthy and malignant prostate tissues with an accuracy of 81%. Even in the presence of substantial tissue heterogeneity, distinct 1 H HR‐MAS spectral patterns were observed for different benign tissue types and prostate cancer. Specifically, healthy glandular tissue was discriminated from prostate cancer based on significantly higher levels of citrate (P = 0.04) and polyamines (P = 0.01), and lower (P = 0.02) levels of the choline‐containing compounds choline, phosphocholine (PC), and glycerophosphocholine (GPC). Predominantly stromal tissue lacked both citrate and polyamines, but demonstrated significantly (P = 0.01) lower levels of choline compounds than cancer. In addition, taurine, myo‐inositol, and scyllo‐inositol were all higher in prostate cancer vs. healthy glandular and stromal tissues. Among cancer samples, larger increases in choline, and decreases in citrate and polyamines (P = 0.05) were observed with more aggressive cancers, and a MIB‐1 labeling index correlated (r = 0.62, P = 0.01) with elevated choline. The elucidation of spectral patterns associated with mixtures of different prostate tissue types and cancer grades, and the inclusion of new metabolic markers for prostate cancer may significantly improve the clinical interpretation of in vivo prostate MRSI data. Magn Reson Med 50:944–954, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Beckonert, O., Keun, H. C., Ebbels, T. M. D., Bundy, J., Holmes, E., Lindon, J. C., & Nicholson, J. K. (2007) · Nature Protocols · doi:10.1038/nprot.2007.376 · Cited by 2,109
Metabolomics-based methods for early disease diagnostics
Gowda, G. N., Zhang, S., Gu, H., Asiago, V., Shanaiah, N., & Raftery, D. (2008) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.8.5.617 · Cited by 692
Imaging Prostate Cancer: A Multidisciplinary Perspective
Hricak, H., Choyke, P. L., Eberhardt, S. C., Leibel, S. A., & Scardino, P. T. (2007) · Radiology · doi:10.1148/radiol.2431030580 · Cited by 601
High-resolution magic-angle-spinning NMR spectroscopy for metabolic profiling of intact tissues
Beckonert, O., Coen, M., Keun, H. C., Wang, Y., Ebbels, T. M. D., Holmes, E., Lindon, J. C., & Nicholson, J. K. (2010) · Nature Protocols · doi:10.1038/nprot.2010.45 · Cited by 381
In Vivo Magnetic Resonance Spectroscopy in Cancer
Gillies, R. J., & Morse, D. L. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100411 · Cited by 261
Metadata
- Authors
- Swanson, M. G., Vigneron, D. B., Tabatabai, Z. L., Males, R. G., Schmitt, L., Carroll, P. R., James, J. K., Hurd, R. E., & Kurhanewicz, J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2003-10-24
- Volume
- 50
- Issue
- 5
- Pages
- 944-954
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2088052532
- Cited by
- 223
- References
- 0
- FWCI
- 7.04
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Proton HR‐MAS spectroscopy and quantitative pathologic analysis of MRI/3D‐MRSI‐targeted postsurgical prostate tissues. https://app.cochat.ai/papers/10.1002/mrm.10614
- The paper
- Swanson, M. G., Vigneron, D. B., Tabatabai, Z. L., Males, R. G., Schmitt, L., Carroll, P. R., James, J. K., Hurd, R. E., & Kurhanewicz, J. (2003). Proton HR‐MAS spectroscopy and quantitative pathologic analysis of MRI/3D‐MRSI‐targeted postsurgical prostate tissues. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10614
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.