Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 261

The DOI matches its Crossref record; 119 of the 119 references it cites were found in a registry or an index.

In Vivo Magnetic Resonance Spectroscopy in Cancer

Gillies, Robert J., Morse, David L.·2005·Annual Review of Biomedical Engineering

Abstract

▪ Abstract Magnetic resonance spectroscopy (MRS) has been used for more than two decades to interrogate metabolite distributions in living cells and tissues. Techniques have been developed that allow multiple spectra to be obtained simultaneously with individual volume elements as small as 1 uL of tissue (i.e., 1 × 1 × 1 mm 3). The most common modern applications of in vivo MRS use endogenous signals from 1 H,31 P, or 23 Na. Important contributions have also been made using exogenous compounds containing 19 F,13 C, or 17 O. MRS has been used to investigate cardiac and skeletal muscle energetics, neurobiology, and cancer. This review focuses on the latter applications, with specific reference to the measurement of tissue choline, which has proven to be a tumor biomarker that is significantly affected by anticancer therapies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1146/annurev.bioeng.7.060804.100411

Cites

119 of 119 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 119 references

Cited by

See all 261

Metadata

Authors
Gillies, R. J., & Morse, D. L.
Venue
Annual Review of Biomedical Engineering
Published
2005-08-15
Volume
7
Issue
1
Pages
287-326
ISSN
  • 1523-9829 (ISSN-L)
  • 1545-4274
OpenAlex
W2129485338
Cited by
261
References
119
FWCI
3.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In Vivo Magnetic Resonance Spectroscopy in Cancer. https://app.cochat.ai/papers/10.1146/annurev.bioeng.7.060804.100411
The paper
Gillies, R. J., & Morse, D. L. (2005). In Vivo Magnetic Resonance Spectroscopy in Cancer. Annual Review of Biomedical Engineering. https://doi.org/10.1146/annurev.bioeng.7.060804.100411

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.