The DOI matches its Crossref record.
VD‐AUTO‐SMASH imaging
Open accessAbstract
Recently a self‐calibrating SMASH technique, AUTO‐SMASH, was described. This technique is based on PPA with RF coil arrays using auto‐calibration signals. In AUTO‐SMASH, important coil sensitivity information required for successful SMASH reconstruction is obtained during the actual scan using the correlation between undersampled SMASH signal data and additionally sampled calibration signals with appropriate offsets in k‐space. However, AUTO‐SMASH is susceptible to noise in the acquired data and to imperfect spatial harmonic generation in the underlying coil array. In this work, a new modified type of internal sensitivity calibration, VD‐AUTO‐SMASH, is proposed. This method uses a VD k‐space sampling approach and shows the ability to improve the image quality without significantly increasing the total scan time. This new k‐space adapted calibration approach is based on a k‐space–dependent density function. In this scheme, fully sampled low‐spatial frequency data are acquired up to a given cutoff‐spatial frequency. Above this frequency, only sparse SMASH‐type sampling is performed. On top of the VD approach, advanced fitting routines, which allow an improved extraction of coil‐weighting factors in the presence of noise, are proposed. It is shown in simulations and in vivo cardiac images that the VD approach significantly increases the potential and flexibility of rapid imaging with AUTO‐SMASH. Magn Reson Med 45:1066–1074, 2001. © 2001 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Contemporary carotid imaging: from degree of stenosis to plaque vulnerability
Brinjikji, W., Huston, J., Rabinstein, A. A., Kim, G.-M., Lerman, A., & Lanzino, G. (2016) · Journal of Neurosurgery · doi:10.3171/2015.1.jns142452 · Cited by 401
Zaitsev, M., Hennig, J., & Speck, O. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20261 · Cited by 349
Parallel magnetic resonance imaging
Larkman, D. J., & Nunes, R. G. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/7/r01 · Cited by 327
Metadata
- Authors
- Heidemann, R. M., Griswold, M. A., Haase, A., & Jakob, P. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2001-05-23
- Volume
- 45
- Issue
- 6
- Pages
- 1066-1074
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2160820770
- Cited by
- 228
- References
- 0
- FWCI
- 8.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: VD‐AUTO‐SMASH imaging. https://app.cochat.ai/papers/10.1002/mrm.1141
- The paper
- Heidemann, R. M., Griswold, M. A., Haase, A., & Jakob, P. M. (2001). VD‐AUTO‐SMASH imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1141
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.