The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Magnet field profiling: Analysis and correcting coil design
Abstract
A full mathematical framework for the analysis and production of localized magnetic field profiles is presented. Of primary use in the production of highly homogeneous fields for nuclear magnetic resonance studies, the paper details the analysis of fields in terms of spherical harmonics, describes how field plotting in the appropriate manner may be used to obtain a direct measure of which harmonics are present, and shows how to combine basic “building blocks” to produce the various lower‐order zonal and tesseral harmonics. “Building blocks” described include coils, arcs, and sinusoids of current as well as rings and arcs of steel. The use of shaped magnets is also briefly mentioned. Attention is drawn to the presence, in high‐order designs, of possibly dominant lower orders of harmonics created by errors in fabrication. The goal of the paper is to present a design philosophy, backed by the appropriate mathematics, which is applicable to the variety of situations encountered in magnet design. Practical examples of correcting coils and “shims” are also given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Methods of Theoretical Physics
Morse, P. M., Feshbach, H., & Hill, E. L. (1954) · American Journal of Physics · doi:10.1119/1.1933765 · Cited by 13,197
Methods of theoretical physics
Domenicali, C. A. (1954) · Journal of the Franklin Institute · doi:10.1016/0016-0032(54)90634-1 · Cited by 4,838
Electrical Current Shims for Correcting Magnetic Fields
Anderson, W. A. (1961) · Review of Scientific Instruments · doi:10.1063/1.1717338 · Cited by 242
Magnetic Resonances of Protons in Ethyl Alcohol
Arnold, J. T. (1956) · Physical Review · doi:10.1103/physrev.102.136 · Cited by 198
On the use of superconducting shields to increase the uniformity of the magnetic field in solenoids
Bychkov, Y. F., Tarutin, O. B., & Uzlov, V. Y. (1975) · Cryogenics · doi:10.1016/0011-2275(75)90038-7 · Cited by 1
Cited by
Automatic, localized in Vivo adjustment of all first‐and second‐order shim coils
Gruetter, R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290613 · Cited by 870
Dynamic multi-coil shimming of the human brain at 7T
Juchem, C., Nixon, T. W., McIntyre, S., Boer, V. O., Rothman, D. L., & de Graaf, R. A. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.07.005 · Cited by 151
Magnetic Field Modeling with a Set of Individual Localized Coils
Juchem, C., Nixon, T. W., McIntyre, S., Rothman, D. L., & Graaf, R. A. D. (2010) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2010.03.008 · Cited by 91
Metadata
- Authors
- Roméo, F., & Hoult, D. I.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1984-03
- Volume
- 1
- Issue
- 1
- Pages
- 44-65
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1976452080
- Cited by
- 388
- References
- 5
- FWCI
- 7.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnet field profiling: Analysis and correcting coil design. https://app.cochat.ai/papers/10.1002/mrm.1910010107
- The paper
- Roméo, F., & Hoult, D. I. (1984). Magnet field profiling: Analysis and correcting coil design. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910010107
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.