The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Magnetic field modeling with a set of individual localized coils
Open accessAbstract
A set of generic, circular individual coils is shown to be capable of generating highly complex magnetic field distributions in a flexible fashion. Arbitrarily oriented linear field gradients can be generated in three-dimensional as well as sliced volumes at amplitudes that allow imaging applications. The multi-coil approach permits the simultaneous generation of linear MRI encoding fields and complex shim fields by the same setup, thereby reducing system complexity. The choice of the sensitive volume over which the magnetic fields are optimized remains temporally and spatially variable at all times. The restriction of the field synthesis to experimentally relevant, smaller volumes such as single slices directly translates into improved efficiency, i.e. higher magnetic field amplitudes and/or reduced coil currents. For applications like arterial spin labeling, signal spoiling and diffusion weighting, perfect linearity of the gradient fields is not required and reduced demands on accuracy can also be readily translated into improved efficiency. The first experimental realization was achieved for mouse head MRI with 24 coils that were mounted on the surface of a cylindrical former. Oblique linear field gradients of 20 kHz/cm (47 mT/m) were generated with a maximum current of 1.4A which allowed radial imaging of a mouse head. The potential of the new approach for generating arbitrary magnetic field shapes is demonstrated by synthesizing the more complex, higher order spherical harmonic magnetic field distributions X2-Y2, Z2 and Z2X. The new multi-coil approach provides the framework for the integration of conventional imaging and shim coils into a single multi-coil system in which shape, strength, accuracy and spatial coverage of the magnetic field can be specifically optimized for the application at hand.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
Lauterbur, P. C. (1973) · Nature · doi:10.1038/242190a0 · Cited by 3,825
Tomographic imaging using the nonlinear response of magnetic particles
Gleich, B., & Weizenecker, J. (2005) · Nature · doi:10.1038/nature03808 · Cited by 2,163
Correction for geometric distortion in echo planar images from B0 field variations
Jezzard, P., & Balaban, R. S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340111 · Cited by 1,428
High-field fMRI unveils orientation columns in humans
Yacoub, E. S., Harel, N., & Uǧurbil, K. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0804110105 · Cited by 564
In Vivo NMR Spectroscopy: Principles and Techniques
de Graaf, R. A. (2019) · Medical Entomology and Zoology · Cited by 510
Self-citationA target field approach to optimal coil design
Turner, R. (1986) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/19/8/001 · Cited by 444
Gradient coil design: A review of methods
Turner, R. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90209-v · Cited by 419
Magnet field profiling: Analysis and correcting coil design
Roméo, F., & Hoult, D. I. (1984) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910010107 · Cited by 388
Image formation by induced local interactions. Examples employing nuclear magnetic resonance. 1973.
Pc, L. (1989) · PubMed · Cited by 343
Laminar specificity of functional MRI onset times during somatosensory stimulation in rat
Silva, A. C., & Koretsky, A. P. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.222561899 · Cited by 262
Novel gradient coils designed using a boundary element method
Poole, M. S., & Bowtell, R. W. (2007) · Concepts in Magnetic Resonance Part B · doi:10.1002/cmr.b.20091 · Cited by 173
Parallel imaging in non-bijective, curvilinear magnetic field gradients: a concept study
Hennig, J., Welz, A. M., Schultz, G., Korvink, J. G., Liu, Z., Speck, O., & Zaitsev, M. (2008) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-008-0105-7 · Cited by 145
Mitigation of susceptibility‐induced signal loss in neuroimaging using localized shim coils
Hsu, J., & Glover, G. H. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20365 · Cited by 97
A multiple-frequency coil with a highly uniform B1 field
Bolinger, L., Prammer, M. G., & LEIGH, J. S. J. (1989) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(89)90274-6 · Cited by 85
General relation for the vector magnetic field of a circular current loop: a closer look
Schill, R. A. (2003) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2003.808597 · Cited by 81
Dynamic shim updating on the human brain
Koch, K. M., McIntyre, S., Nixon, T. W., et al. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.03.007 · Cited by 78
Self-citationJuchem, C., Nixon, T. W., McIntyre, S., Rothman, D. L., & de Graaf, R. A. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22164 · Cited by 72
Self-citationGradient coil design using active magnetic screening
Bowtell, R. W., & Mansfield, P. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170105 · Cited by 61
Combined passive and active shimming for in vivo MR spectroscopy at high magnetic fields
Juchem, C., Müller‐Bierl, B., Schick, F., Logothetis, N. K., & Pfeuffer, J. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.09.002 · Cited by 61
Self-citationUltrashort shielded gradient coil design with 3D geometry
Shvàrtsman, S. M., Morich, M. A., DeMeester, G. D., et al. (2005) · Concepts in Magnetic Resonance Part B · doi:10.1002/cmr.b.20044 · Cited by 45
Field ion energy deficit calculations for liquid metal ion sources
de Castilho, C. M. C., & Kingham, D. R. (1986) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/19/1/019 · Cited by 43
Short Planar Gradient Coils for MR Microscopy Using Concentric Return Paths
Dodd, S. J., & Ho, C. (2002) · Journal of Magnetic Resonance · doi:10.1006/jmre.2002.2532 · Cited by 28
Seo, Y., Shinar, H., Morita, Y., & Navon, G. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3 · Cited by 19
Magnetic resonance imaging with composite (dual) gradients
Parker, D. L., Goodrich, K. C., Hadley, J. R., et al. (2009) · Concepts in Magnetic Resonance Part B · doi:10.1002/cmr.b.20134 · Cited by 17
Fast two-dimensional MR imaging by Multiple Acquisition with Micro B0 Array (MAMBA)
Lee, K. J., Paley, M. N. J., Wilkinson, I. D., et al. (2002) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(02)00488-5 · Cited by 10
Target field design for MAMBA step fields
Lee, K. J., Paley, M. N. J., Barber, D. C., et al. (2004) · Concepts in Magnetic Resonance Part B · doi:10.1002/cmr.b.20001 · Cited by 7
Hexagonal surface gradient coil for localized MRS of the heart
Jasiński, A. H., Kozłowski, P., Urbanski, A., et al. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910210214 · Cited by 7
Flagged first, then by citations
Research works printed but not linked: 3
- Aiken, 1995, A review of NMR microimaging studies of single cells, J. Magn. Reson. Anal., 1, 41
- C. Juchem, D.L. Rothman, R.A. de Graaf, First-to-fourth Order Spherical Harmonics Shimming with a Grid of Circular Electrical Coils, ISMRM, Annual Meeting, Honolulu, HI/USA, 2009, pp. 3081.
- C. Juchem, T.W. Nixon, M. Abildgaard, S. McIntyre, D.L. Rothman, R.A. de Graaf, Whole Brain Field Homogenization with Localized Electrical Coils, ISMRM, Annual Meeting, Honolulu, HI/USA, 2009, pp. 3079.
Cited by
Sorted by citations
Dynamic multi-coil shimming of the human brain at 7T
Juchem, C., Nixon, T. W., McIntyre, S., Boer, V. O., Rothman, D. L., & de Graaf, R. A. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.07.005 · Cited by 151
Self-citationHolmes, N., Rea, M., Hill, R. M., Leggett, J., Edwards, L. J., Hobson, P. J., Boto, E., Tierney, T. M., Rier, L., Rivero, G. R., et al. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120157 · Cited by 89
Juchem, C., Umesh Rudrapatna, S., Nixon, T. W., & de Graaf, R. A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.11.011 · Cited by 74
Self-citationNaturalistic Hyperscanning with Wearable Magnetoencephalography
Holmes, N., Rea, M., Hill, R. M., Boto, E., Leggett, J., Edwards, L. J., Rhodes, N., Shah, V., Osborne, J., Fromhold, T. M., et al. (2023) · Sensors · doi:10.3390/s23125454 · Cited by 52
“Superposition of the magnetic field generated by multiple coils, each carrying an independently controllable current, enables the production of arbitrary patterns of magnetic field variation within a selected target volume (Garda and Galias, 2014; Juchem et al., 2010).”
Background
Metadata
- Authors
- Juchem, C., Nixon, T. W., McIntyre, S., Rothman, D. L., & Graaf, R. A. D.
- Affiliations
- Yale University (US)
- Corresponding author
- Juchem, Christoph
- Venue
- Journal of Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2010-06
- Volume
- 204
- Issue
- 2
- Pages
- 281-289
- ISSN
- 1090-7807 (ISSN-L)
- PMC
- PMC2884296
- OpenAlex
- W2056310784
- Cited by
- 91
- References
- 27
- Citations by year
- 2026: 2 · 2025: 6 · 2024: 6 · 2023: 6 · 2022: 11 · 2021: 6 · 2020: 2 · 2019: 8 · 2018: 4 · 2017: 7 · 2016: 2 · 2015: 5 · 2014: 7 · 2013: 5 · 2012: 7
- FWCI
- 4.94
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- Locations
- Journal of Magnetic Resonance (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health
- National Cancer Institute (R33CA118503, R21CA118503, R21/R33-CA118503)
- National Institute of Neurological Disorders and Stroke (P30NS052519)
- National Institute of Biomedical Imaging and Bioengineering (R01EB000473)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Keywords
- arterial spin labeling
- MeSH terms
- Computer Simulation, Electromagnetic Fields, Equipment Design, Magnetic Resonance Imaging, Magnetics, Models, Theoretical, Transducers, Computer-Aided Design, Equipment Failure Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review