Concurrent measurements of cerebral blood flow, sodium, lactate, and high‐energy phosphate metabolism using 19F, 23Na, 1H, and 31P nuclear magnetic resonance spectroscopy
The DOI matches its Crossref record.
Abstract
A new NMR technique for nondestructive, noninvasive, nonradioactive concurrent measurements of blood flow and several energy‐dependent metabolites were applied to in situ cat brain during high cerebral blood flow states (seizures) and low flow states (carotid occlusion plus hemorrhagic shock). An inductively coupled, quadruple‐tuned surface coil with a 50‐ohm match at all relevant frequencies was used for both excitation and receiving. A broadband spectometer was used to measure the 31 P spectrum (PCr, ATP, Pi, and pH), a water‐suppressed 1 H spectrum (lactate), 23 Na, and 19 F (blood flow via CHF 3 washout). Each nucleus was excited at an independently determined rate. Sodium, with a short T1, was excited more frequently than phosphorus. The results qualitatively agreed with other techniques. Blood flow greatly increased during seizures with a 10% decrease in the Na signal, minimal lactate accumulation, no pH shift, and a change in the PCr‐to‐Pi ratio from 3.4 to 1.7. During carotid occlusion plus hypotension blood flow, PCr and ATP decreased to less than 10% of baseline values. Changes in PCr and Pi preceded parallel changes in Na and ATP. These experiments demonstrated the feasibility of concurrent measurements of physiologically induced changes in high‐energy phosphates, lactate, sodium, and blood flow from the same volume of brain, in a nondestructive manner using NMR spectroscopy. © 1988 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Magnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
Self-citationMethodology of brain perfusion imaging
Barbier, E. L., Lamalle, L., & Décorps, M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1073 · Cited by 404
Applications of arterial spin labeled MRI in the brain
Detre, J. A., Rao, H., Wang, D. J. J., Chen, Y. F., & Wang, Z. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23581 · Cited by 326
Le Bihan, D., Turner, R., Moonen, C. T. W., & Pekar, J. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010103 · Cited by 288
Carlier, P. G., Marty, B., Scheidegger, O., Loureiro de Sousa, P., Baudin, P.-Y., Snezhko, E., & Vlodavets, D. (2016) · Journal of Neuromuscular Diseases · doi:10.3233/jnd-160145 · Cited by 186
“The concept of acquiring several NMR variables of interest in a single sequence is not a novel one [28, 71, 242].”
Background
Metadata
- Authors
- Eleff, S. M., Schnall, M. D., Ligetti, L., Osbakken, M., Subramanian, H., Chance, B., & Leigh, J. S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1988-08
- Volume
- 7
- Issue
- 4
- Pages
- 412-424
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2092598059
- Cited by
- 93
- References
- 0
- FWCI
- 9.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Concurrent measurements of cerebral blood flow, sodium, lactate, and high‐energy phosphate metabolism using 19F, 23Na, 1H, and 31P nuclear magnetic resonance spectroscopy. https://app.cochat.ai/papers/10.1002/mrm.1910070404
- The paper
- Eleff, S. M., Schnall, M. D., Ligetti, L., Osbakken, M., Subramanian, H., Chance, B., & Leigh, J. S. (1988). Concurrent measurements of cerebral blood flow, sodium, lactate, and high‐energy phosphate metabolism using 19F, 23Na, 1H, and 31P nuclear magnetic resonance spectroscopy. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910070404
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.