In vivo localized ESR spectroscopy reflecting metabolism
The DOI matches its Crossref record.
Abstract
Localized electron spin resonance spectroscopy in Live mice was performed using a surface coil operating at 1.1 GHz with sufficient sensitivity and stability to measure quantitatively the time course of the distribution, uptake, and reduction of nitroxides in selected organsfregions (liver, bladder, head) of mice. The ability to measure regional concentrations of nitroxides in vivo could be used for pharmacokinetic analysis of drugs labeled with nitroxides and for measurement of oxygen concentrations and redox metabolism. © 1989 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nagano, T., & Yoshimura, T. (2002) · Chemical Reviews · doi:10.1021/cr010152s · Cited by 414
Noninvasive detection of hydroxyl radical generation in lung by diesel exhaust particles
Han, J.-Y., Takeshita, K., & Utsumi, H. (2001) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(00)00501-3 · Cited by 148
Trityl-based EPR probe with enhanced sensitivity to oxygen
Bobko, A. A., Dhimitruka, I., Eubank, T. D., Marsh, C. B., Zweier, J. L., & Khramtsov, V. V. (2009) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2009.06.007 · Cited by 63
In vivo Spectroscopy and Imaging of Nitroxide Probes
V., V. (2012) · Nitroxides - Theory, Experiment and Applications · doi:10.5772/39129 · Cited by 8
“Initially, the paramagnetic probes for EPR oximetry were almost exclusively nitroxides (Backer et al., 1977; Lai et al., 1982; Froncisz et al., 1985; Bacic et al., 1989; Chan et al., 1989; Hyde & Subszynski, 1989).”
Metadata
- Authors
- Bacic, G., Nilges, M. J., Magin, R. L., Walczak, T., & Swartz, H. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1989-05
- Volume
- 10
- Issue
- 2
- Pages
- 266-272
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2079629366
- Cited by
- 131
- References
- 0
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.