Cited by 8Electron Spin Resonance StudiesAdvanced NMR Techniques and ApplicationsMagnetism in coordination complexes

The DOI matches its Crossref record; 130 of the 132 references it cites were found in a registry or an index.

In vivo Spectroscopy and Imaging of Nitroxide Probes

Open access
V., Valery·2012·Nitroxides - Theory, Experiment and Applications

Abstract

Book chapter from "Nitroxides - Theory, Experiment and Applications", edited by Alexander I. Kokorin, ISBN 978-953-51-0722-4, Hard cover, 436 pages, InTech, September 12, 2012.\nDOI: 10.5772/2887

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5772/39129

Cites

130 of 130 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • EPR oximetry is a relatively simple, non-invasive method to measure oxygen levels in biological systems using implanted and soluble paramagnetic probes.

    “EPR oximetry is a relatively simple, non-invasive method to measure oxygen levels in biological systems using implanted and soluble paramagnetic probes, the use of which has been gradually increasing [27–30].”

    From Direct Measurements of Oxygen Gradients in Spheroid Culture System Using Electron Parametric Resonance Oximetry (2016) · cites this paper as [27]

    Section 2.1 describes EPR oximetry as a basis for non-invasive oxygen measurement in biological systems and identifies both implantable particulate probes and soluble probes. It also calls the technique rapidly developing, but does not characterize it as relatively simple. (LLM, conf=0.85)

    Experimental — accuracy not yet measured
  • One advantage of EPR-based methodology over micro-electrode measurements is that linewidth of spectra is based on pure physical interaction between paramagnetic probe molecules and oxygen within the biological system.

    “One advantage which EPR based methodology has over normal micro-electrode measurements is that linewidth of spectra is based on pure physical interaction between paramagnetic probe molecules and oxygen within the biological system [27].”

    From Direct Measurements of Oxygen Gradients in Spheroid Culture System Using Electron Parametric Resonance Oximetry (2016) · cites this paper as [27]

    Section 2.1 (page not available) says EPR oximetry relies on a physical interaction between paramagnetic probes and oxygen, and describes oxygen-induced spectral broadening. It does not compare this advantage with micro-electrode measurements, so that comparative part is not supported by our copy. (LLM, conf=0.84)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

2 of the 132 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Metadata

Authors
V., V.
Venue
Nitroxides - Theory, Experiment and Applications
Publisher
InTech
Published
2012-09-12
OpenAlex
W1534222630
Cited by
8
References
132
Citations by year
2025: 2 · 2021: 1 · 2020: 2 · 2017: 1 · 2016: 2
FWCI
0.00
Type
book chapter
Language
en
Open access
Licence
cc-by
Locations
  • InTech eBooks (publishedVersion, cc-by)
  • BiblioBoard Library Catalog (Open Research Library) (submittedVersion, cc-by)
  • Contact-less Assessment of In-vivo Body Signals Using Microwave Doppler Radar (InTech) (submittedVersion, cc-by)
  • The Knowledge Bank (The Ohio State University) (submittedVersion, cc-by)
Funders
National Institutes of Health (EB014542)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Electron Spin Resonance Studies
  • Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Magnetism in coordination complexes
Keywords
nitroxide probes, in vivo spectroscopy, in vivo imaging, nitroxide radicals, spin-labeled probes, magnetic resonance imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review