The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Signal‐to‐noise in phase angle reconstruction: Dynamic range extension using phase reference offsets
Abstract
The dynamic range of phase‐reconstructed magnetic resonance images is compared to that of magnitude‐reconstructed images. From analysis of propagation of errors, the phase angle noise is phase‐independent and given in radians by σ (|I|)/|I|, the noise‐to‐signal ratio of the corresponding magnitude‐reconstructed image. As the phase can range from minus π to π the phase angle dynamic range is 2π times that of the signal magnitude. These results agree with experiment, verifying that the noise in the two receiver channels is uncorrelated. An artifact‐free technique is presented for correcting phase spillover, which further extends the phase angle dynamic range. The reconstruction‐based reference phase is adjusted on a local basis so that the boundary of phase wraparound is reconstructed near the center of the [ − π, π] interval. For a particular flow study, the phase signal‐to‐noise was extended over twofold by spillover correction, to a value 15 times that of the magnitude signal‐to‐noise. © 1990 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Cited by
de Rochefort, L., Liu, T., Kressler, B., Liu, J., Spincemaille, P., Lebon, V., Wu, J., & Wang, Y. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22187 · Cited by 670
Encoding strategies for three‐direction phase‐contrast MR imaging of flow
Pelc, N. J., Bernstein, M. A., Shimakawa, A., & Glover, G. H. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010404 · Cited by 455
Liu, T., Spincemaille, P., de Rochefort, L., Kressler, B., & Wang, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21828 · Cited by 454
Ex vivo tissue‐type independence in proton‐resonance frequency shift MR thermometry
Peters, R. T. D., Hinks, R. S., & Henkelman, R. M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400316 · Cited by 320
Plewes, D. B., Bishop, J., Samani, A., & Sciarretta, J. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/314 · Cited by 318
Metadata
- Authors
- Conturo, T. E., & Smith, G. D.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1990-09
- Volume
- 15
- Issue
- 3
- Pages
- 420-437
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2013778198
- Cited by
- 205
- References
- 1
- FWCI
- 3.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Signal‐to‐noise in phase angle reconstruction: Dynamic range extension using phase reference offsets. https://app.cochat.ai/papers/10.1002/mrm.1910150308
- The paper
- Conturo, T. E., & Smith, G. D. (1990). Signal‐to‐noise in phase angle reconstruction: Dynamic range extension using phase reference offsets. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910150308
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.