CoChat

Tissue perfusion in humans studied by fourier velocity distribution, line scan, and echo‐planar imaging

Feinberg, David A., Jakab, Peter D. · 1990 · Magnetic Resonance in Medicine
Cited by 44

The DOI matches its Crossref record.

Abstract

In tissue perfusion studies, FT velocity distribution imaging (VDI) intrinsically distinguishes signals from moving blood and volume‐averaged tissue. Results in human thyroid gland, in vivo, using VDI line scan technique demonstrated separation of moving blood signal from glandular tissue. while VDI inner‐volume echo‐planar imaging of brain showed only CSF velocity above the image noise level. New alternating polarity gradient sequences which permit separation of diffusion and slow velocity are discussed. A novel method of 3D FT imaging (two spatial and one velocity dimension) combining inner‐volume imaging and echo‐planar imaging with velocity resolution of 0.15 mm / s per pixel is demonstrated. A novel graphical method of calculation and display of diffusion dependence in pulsed gradient sequences is presented. © 1990 Academic Press, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910160209

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 44

Metadata

Authors
Feinberg, D. A., & Jakab, P. D.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1990-11
Volume
16
Issue
2
Pages
280-293
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2122493616
Cited by
44
References
0
FWCI
2.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tissue perfusion in humans studied by fourier velocity distribution, line scan, and echo‐planar imaging. https://app.cochat.ai/papers/10.1002/mrm.1910160209
The paper
Feinberg, D. A., & Jakab, P. D. (1990). Tissue perfusion in humans studied by fourier velocity distribution, line scan, and echo‐planar imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910160209

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.