Tissue perfusion in humans studied by fourier velocity distribution, line scan, and echo‐planar imaging
The DOI matches its Crossref record.
Abstract
In tissue perfusion studies, FT velocity distribution imaging (VDI) intrinsically distinguishes signals from moving blood and volume‐averaged tissue. Results in human thyroid gland, in vivo, using VDI line scan technique demonstrated separation of moving blood signal from glandular tissue. while VDI inner‐volume echo‐planar imaging of brain showed only CSF velocity above the image noise level. New alternating polarity gradient sequences which permit separation of diffusion and slow velocity are discussed. A novel method of 3D FT imaging (two spatial and one velocity dimension) combining inner‐volume imaging and echo‐planar imaging with velocity resolution of 0.15 mm / s per pixel is demonstrated. A novel graphical method of calculation and display of diffusion dependence in pulsed gradient sequences is presented. © 1990 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics
Sarvazyan, A. P., Rudenko, O. V., Swanson, S. D., Fowlkes, J. B., & Emelianov, S. Y. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00110-0 · Cited by 1,727
Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015710 · Cited by 1,296
“The twice-refocused diffusion encoding sequence, first described by Feinberg and Jacob [48], was incorporated into the M-EPI sequence by methods earlier reported using SIR alone [48,49].”
MethodSelf-citationSetsompop, K., Gagoski, B. A., Polimeni, J. R., Witzel, T., Wedeen, V. J., & Wald, L. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23097 · Cited by 1,285
“The SE-EPI diffusion-weighted imaging was performed with a twice-refocused sequence (21,22) using either conventional single-slice imaging or a 3 slice-accelerated simultaneous multislice acquisition.”
MethodUğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Self-citationUltra-fast MRI of the human brain with simultaneous multi-slice imaging
Feinberg, D. A., & Setsompop, K. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2013.02.002 · Cited by 433
Self-citation
Metadata
- Authors
- Feinberg, D. A., & Jakab, P. D.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1990-11
- Volume
- 16
- Issue
- 2
- Pages
- 280-293
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2122493616
- Cited by
- 44
- References
- 0
- FWCI
- 2.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tissue perfusion in humans studied by fourier velocity distribution, line scan, and echo‐planar imaging. https://app.cochat.ai/papers/10.1002/mrm.1910160209
- The paper
- Feinberg, D. A., & Jakab, P. D. (1990). Tissue perfusion in humans studied by fourier velocity distribution, line scan, and echo‐planar imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910160209
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.