Rapid in vivo proton shimming
Abstract
A rapid and completely automated method of adjusting the magnetic field (B0) homogeneity for in vivo proton spectroscopy and imaging is described. Bo inhomogeneity maps are generated by a gradient‐recalled echo pulse sequence in which the frequency dispersion is chosen to eliminate the effects of the fat/water chemical shift. Low‐order shim values are derived by magnitude‐weighted least‐squares fits to the B0 maps and automatically applied as DC offsets to the X, Y, and Z gradient amplifiers. Imaging with chemical shift selective saturation is used as a measure of the efficacy of the technique. Results indicate that AUTOSHIM improves the overall homogeneity; however, local high‐order field distortions which cannot be corrected by linear gradients are generated by certain air/tissue and bone/tissue morphology. In such cases a “ZOOM SHIM” may be applied over a limited region of interest for local homogeneity improvement at the expense of other regions. It is suggested that such scans are a necessity for recording the homogeneity during clinical MR spectroscopy. © 1991 Academic Press. Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Automatic, localized in Vivo adjustment of all first‐and second‐order shim coils
Gruetter, R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290613 · Cited by 870
Methodological consensus on clinical proton MRS of the brain: Review and recommendations
Wilson, M., Andronesi, O., Barker, P. B., Bartha, R., Bizzi, A., Bolan, P. J., Brindle, K. M., Choi, I., Cudalbu, C., Dydak, U., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27742 · Cited by 470
Multi-parametric neuroimaging reproducibility: A 3-T resource study
Landman, B. A., Huang, A. J., Gifford, A., Vikram, D. S., Lim, I. A. L., Farrell, J. A. D., Bogovic, J. A., Hua, J., Chen, M., Jarso, S., et al. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.11.047 · Cited by 299
Magnetic field changes in the human brain due to swallowing or speaking
Birn, R. M., Bandettini, P. A., Cox, R. W., Jesmanowicz, A., & Shaker, R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400108 · Cited by 172
Formalin tissue fixation biases myelin – sensitive MRI
Seifert, A. C., Umphlett, M., Hefti, M., Fowkes, M., & Xu, J. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27821 · Cited by 44
Metadata
- Authors
- Schneider, E., & Glover, G.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1991-04
- Volume
- 18
- Issue
- 2
- Pages
- 335-347
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1992347375
- Cited by
- 221
- References
- 0
- FWCI
- 5.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid in vivo proton shimming. https://app.cochat.ai/papers/10.1002/mrm.1910180208
- The paper
- Schneider, E., & Glover, G. (1991). Rapid in vivo proton shimming. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910180208
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.