Diffusion imaging using stimulated echoes
Open accessThe DOI matches its Crossref record.
Abstract
The application of stimulated echo acquisition mode (STEAM) sequences for NMR imaging of diffusion is especially suited for spins with T1 ≫ T2 as, e.g., encountered in proton NMR studies of biological systems. Molecular self‐diffusion coefficients may be calculated from a set of diffusion‐weighted images acquired with different gradient strengths. A variation of the diffusion time allows the determination of restricted and/or anisotropic diffusion in cellular systems ranging from plants to humans. Problems associated with the presence of unavoidable macroscopic motions in vivo are demonstrated in diffusion studies of human brain. Motion ghosting in diffusion‐weighted images may be overcome by means of a high‐speed STEAM sequence yielding single‐shot images within subsecond acquisition times. © 1991 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Orientationally invariant indices of axon diameter and density from diffusion MRI
Alexander, D. C., Hubbard, P. L., Hall, M. G., Moore, E. A., Ptito, M., Parker, G. J. M., & Dyrby, T. B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.043 · Cited by 683
“Stanisz et al. (1997) fit the threecompartment model to 800 nuclear magnetic resonance (NMR) measurements of a fixed sample using a stimulated echo sequence (Merboldt et al., 1991) with 3 ms pulses and varying diffusion time and gradient strength.”
BackgroundImaging brain microstructure with diffusion MRI: practicality and applications
Alexander, D. C., Dyrby, T. B., Nilsson, M., & Zhang, H. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3841 · Cited by 424
Alexander, D. C. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21646 · Cited by 331
Leergaard, T. B., White, N. S., de Crespigny, A., Bolstad, I., D'Arceuil, H., Bjaalie, J. G., & Dale, A. M. (2010) · PLoS ONE · doi:10.1371/journal.pone.0008595 · Cited by 179
Richardson, S., Siow, B., Panagiotaki, E., Schneider, T., Lythgoe, M. F., & Alexander, D. C. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25012 · Cited by 27
Metadata
- Authors
- Merboldt, K., Hänicke, W., & Frahm, J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1991-06
- Volume
- 19
- Issue
- 2
- Pages
- 233-239
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2028667285
- Cited by
- 110
- References
- 0
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diffusion imaging using stimulated echoes. https://app.cochat.ai/papers/10.1002/mrm.1910190208
- The paper
- Merboldt, K., Hänicke, W., & Frahm, J. (1991). Diffusion imaging using stimulated echoes. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910190208
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.