Restricted and anisotropic displacement of water in healthy cat brain and in stroke studied by NMR diffusion imaging
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The occlusion of the middle cerebral artery in cat brain was used as an experimental stroke model to investigate the physical basis of the recently reported lowered diffusion constant of water in acute infarcted brain tissue (Moseley et al., Magn. Reson. Med. 14, 330, 1990). The original findings were confirmed in this study of 12 animals investigated with the diffusion‐sensitized stimulated echo sequence. The following additional results were obtained: First, the onset of significant lowering of the diffusion constant in the stroke area varied significantly (up to 2.5 h depending on the animal). Second, the affected area is much more clearly outlined in diffusion‐weighted images than in T 2,‐weighted images, even in the period between 3 to 12 h following occlusion. Third, for diffusion times between 50 and 2000 ms, the diffusion constant of water is independent of diffusion time in healthy tissue, as well as in the stroke area. Fourth, the diffusion anisotropy is similar in healthy and in stroke area and remains similar regardless of the diffusion time used. © 1991 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Cited by
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Diffusion tensor imaging: Concepts and applications
Le Bihan, D., Mangin, J., Poupon, C., Clark, C. A., Pappata, S., Molko, N., & Chabriat, H. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1076 · Cited by 3,547
“The facts are that: a) water diffusion is highly anisotropic in white matter (10–12); b) such anisotropy has been observed even before fibers are myelinated, although to a lesser degree (43,43,77,97–102); and c) the ADCs measured in parallel and perpendicularly to the fibers do not seem to depend on the diffusion time…”
BackgroundLooking into the functional architecture of the brain with diffusion MRI.
Le Bihan, D. (2003) · Nature Reviews Neuroscience · doi:10.1038/nrn1119 · Cited by 1,571
“; and third, ADCs that are measured parallel and perpendicular to the fibres do not seem to depend on diffusion tim”
BackgroundDiffusion-weighted MR Imaging of the Brain
Schaefer, P. W., Grant, P. E., & Gonzalez, R. G. (2000) · Radiology · doi:10.1148/radiology.217.2.r00nv24331 · Cited by 1,052
Diffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Metadata
- Authors
- Moonen, C. T. W., Pekar, J., de Vleeschouwer, M. H. M., van Gelderen, P., van Zijl, P. C. M., & Despres, D.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1991-06
- Volume
- 19
- Issue
- 2
- Pages
- 327-332
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2066952917
- Cited by
- 129
- References
- 1
- FWCI
- 7.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.