Design and evaluation of shielded gradient coils
The DOI matches its Crossref record.
Abstract
Techniques are described for the design of shielded gradient coils for superconducting MRI systems. These design methods are suited for constructing the most efficient gradient coil that meets a specified homogeneity requirement. Tradeoffs in coil design of efficiency with coil size and gap size are discussed. Residual eddy currents from coils constructed with a finite number of wires are calculated and give guidelines for the construction of efficient, whole‐body gradient coils.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Moving magnetoencephalography towards real-world applications with a wearable system
Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., et al. (2018) · Nature · doi:10.1038/nature26147 · Cited by 1,377
“The coils were designed25,26 on two 1.6 x 1.6 m 2 planes, placed either side of the subject with a 1.5 m separation (Figure 3a).”
InfluentialGradient coil design: A review of methods
Turner, R. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90209-v · Cited by 418
Holmes, N., Leggett, J., Boto, E., Roberts, G., Hill, R. M., Tierney, T. M., Shah, V., Barnes, G. R., Brookes, M. J., & Bowtell, R. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.07.028 · Cited by 250
“Magnetoencephalography (MEG) is a method for non-invasively mapping electrophysiological activity in the human brain (Cohen, 1968).”
MethodNovel gradient coils designed using a boundary element method
Poole, M., & Bowtell, R. (2007) · Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering · doi:10.1002/cmr.b.20091 · Cited by 173
Holmes, N., Tierney, T. M., Leggett, J., Boto, E., Mellor, S., Roberts, G., Hill, R. M., Shah, V., Barnes, G. R., Brookes, M. J., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-50697-w · Cited by 163
Metadata
- Authors
- Carlson, J. W., Derby, K. A., Hawryszko, K. C., & Weideman, M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1992-08
- Volume
- 26
- Issue
- 2
- Pages
- 191-206
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2021771641
- Cited by
- 105
- References
- 0
- FWCI
- 3.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and evaluation of shielded gradient coils. https://app.cochat.ai/papers/10.1002/mrm.1910260202
- The paper
- Carlson, J. W., Derby, K. A., Hawryszko, K. C., & Weideman, M. (1992). Design and evaluation of shielded gradient coils. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910260202
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.