The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Balanced, bi-planar magnetic field and field gradient coils for field compensation in wearable magnetoencephalography
Open accessAbstract
Abstract To allow wearable magnetoencephalography (MEG) recordings to be made on unconstrained subjects the spatially inhomogeneous remnant magnetic field inside the magnetically shielded room (MSR) must be nulled. Previously, a large bi-planar coil system which produces uniform fields and field gradients was used for this purpose. Its construction presented a significant challenge, six distinct coils were wound on two 1.6 × 1.6 m2 planes. Here, we exploit shared coil symmetries to produce coils simultaneously optimised to generate homogenous fields and gradients. We show nulling performance comparable to that of a six-coil system is achieved with this three-coil system, decreasing the strongest field component Bx by a factor of 53, and the strongest gradient dBx/dz by a factor of 7. To allow the coils to be used in environments with temporally-varying magnetic interference a dynamic nulling system was developed with a shielding factor of 40 dB at 0.01 Hz. Reducing the number of coils required and incorporating dynamic nulling should allow for greater take-up of this technology. Interactions of the coils with the high-permeability walls of the MSR were investigated using a method of images approach. Simulations show a degrading of field uniformity which was broadly consistent with measured values. These effects should be incorporated into future designs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
OPM-MEG experiments involving participant motion require an OPM-optimised MSR with a very low remnant magnetic field and active magnetic shielding.
“These constraints mean that OPM-MEG experiments involving participant motion require an OPM-optimised MSR with a very low remnant magnetic field along with ‘active’ magnetic shielding”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [37]
The Introduction (page unavailable) explains that motion can move OPMs outside their narrow operating range and that field-compensating coils enabled recordings during large participant movements. It also says dynamic compensation is required to address field drift. However, the paper describes using coils inside a two-layer magnetically shielded room; it does not establish that a specially OPM-optimised room is required. (LLM, conf=0.86)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moving magnetoencephalography towards real-world applications with a wearable system
Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., et al. (2018) · Nature · doi:10.1038/nature26147 · Cited by 1,377
Self-citationBoto, E., Meyer, S. S., Shah, V., Alem, O., Knappe, S., Kruger, P., Fromhold, T. M., Lim, M., Glover, P. M., Morris, P. G., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.034 · Cited by 471
Self-citationOptically pumped magnetometers: from quantum origins to multi-channel magnetoencephalography
Tierney, T. M., Holmes, N., Mellor, S., López, J. D., Roberts, G., Hill, R. M., Boto, E., Leggett, J., Shah, V., Brookes, M. J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.063 · Cited by 400
Self-citationMeasuring MEG Closer to the Brain: Performance of on-Scalp Sensor Arrays
Iivanainen, J., Stenroos, M., & Parkkonen, L. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.048 · Cited by 296
Flagged first, then by citations
Research works printed but not linked: 21
- Cohen, D. Magnetoencephalography: evidence of magnetic fields produced by alpha rhythm currents. Science 161, 784–786 (1968). · DOI · Paper page
- Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J. & Lounasmaa, O. V. Magnetoencephalography theory, instrumentation, and applications to noninvasive studies of the working human brain. Rev. Mod. Phys. 65, 413–497 (1993). · DOI · Paper page
- Witton, C., Furlong, P. L. & Seri, S. Technological challenges of pediatric MEG and potential solutions: The Aston experience. In Magnetoencephalography: From Signals to Dynamic Cortical Networks, https://doi.org/10.1007/978-3-642-33045-2_30 (2014). · DOI
- Borna, A. et al. A 20-channel magnetoencephalography system based on optically pumped magnetometers. Phys. Med. Biol. 62, 8909–8923 (2017). · DOI
- Shah, V. K. & Wakai, R. T. A compact, high performance atomic magnetometer for biomedical applications. Phys. Med. Biol. 58, 8153–8161 (2013). · DOI · Paper page
- Holmes, N. et al. A bi-planar coil system for nulling background magnetic fields in scalp mounted magnetoencephalography. Neuroimage, https://doi.org/10.1016/j.neuroimage.2018.07.028(2018). · DOI · Paper page
- Tierney, T. M. et al. Cognitive neuroscience using wearable magnetometer arrays: Non-invasive assessment of language function. Neuroimage 181, 513–520 (2018). · DOI
- Kastler, A. The Hanle effect and its use for the measurements of very small magnetic fields. Nucl. Instruments Methods 110, 259–265 (1973). · DOI
- Shah, V., Osborne, J., Orton, J. & Alem, O. Fully integrated, standalone zero field optically pumped magnetometer for biomagnetism. Steep Dispers. Eng. Opto-Atomic Precis. Metrol. X I 51, https://doi.org/10.1117/12.2299197 (2018). · DOI
- Iivanainen, J., Zetter, R., Grön, M., Hakkarainen, K. & Parkkonen, L. On-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers. Neuroimage, https://doi.org/10.1016/j.neuroimage.2019.03.022 (2019). · DOI · Paper page
- Moon, C. H., Park, H. W. & Lee, S. Y. A design method for minimum-inductance planar magnetic-resonance-imaging gradient coils considering the pole-piece effect. Meas. Sci. Technol. 10 (1999). · DOI
- Juhas, A., Pekari, N. & Toepfer, H. Magnetic Field of Rectangular Current Loop with Sides Parallel and Perpendicular to the Surface of High-permeability Material. 11, 701–717 (2014). · DOI
- Qinjie, C. et al. Optimization of a Coil System for Generating Uniform Magnetic Fields inside a Cubic. Energies 11, 608 (2018). · DOI
- Turner, R. Gradient coil design: A review of methods. Magnetic Resonance Imaging 11, 903–920 (1993). · DOI
- Carlson, J. W., Derby, K. A., Hawryszko, K. C. & Weideman, M. Design and evaluation of shielded gradient coils. Magn. Reson. Med. 26, 191–206 (1992). · DOI
- Yoda, K. Analytical design method of self-shielded planar coils. J. Appl. Phys. 67, 4349–4353 (1990). · DOI
- Dupont-Roc, J., Haroche, S. & Cohen-Tannoudji, C. Detection of very weak magnetic fields (10−9gauss) by 87Rb zero-field level crossing resonances. Phys. Lett. A 28, 638–639 (1969). · DOI
- Hoburg, J. F. Principles of Quasistatic Magnetic Shielding with Cylindrical and Spherical Shields. IEEE Transactions on Electromagnetic Compatibility, https://doi.org/10.1109/15.477342 (1995). · DOI
- Hammond, P. Electric and magnetic images. Proc. IEE Part C Monogr. 107, 306 (1960). · DOI
- Roshen, W. A. Effect of Finite Thickness of Magnetic Substrate on Planar Inductors. IEEE Trans. Magn. 26, 270–275 (1990). · DOI
- Martens, M. A. et al. Insertable biplanar gradient coils for magnetic resonance imaging. Rev. Sci. Instrum. 62, 2639–2645 (1991). · DOI
Cited by
Sorted by citations
Multi-Channel Whole-Head OPM-MEG: Helmet Design and a Comparison with a Conventional System
Hill, R. M., Boto, E., Rea, M., Holmes, N., Leggett, J., Coles, L. A., Papastavrou, M., Everton, S. K., Hunt, B. A. E., Sims, D., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116995 · Cited by 285
Self-citationA lightweight magnetically shielded room with active shielding
Holmes, N., Rea, M., Chalmers, J., Leggett, J., Edwards, L. J., Nell, P., Pink, S., Patel, P., Wood, J., Murby, N., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-17346-1 · Cited by 121
Self-citationA 90-Channel Triaxial Magnetoencephalography System Using Optically Pumped Magnetometers
Rea, M., Boto, E., Holmes, N., Hill, R., Osborne, J., Rhodes, N., Leggett, J., Rier, L., Bowtell, R., Shah, V., et al. (2022) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.14890 · Cited by 102
Self-citationUsing OPMs to measure neural activity in standing, mobile participants
Seymour, R. A., Alexander, N., Mellor, S., O'Neill, G. C., Tierney, T. M., Barnes, G. R., & Maguire, E. A. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118604 · Cited by 102
Self-citationHolmes, N., Rea, M., Hill, R. M., Leggett, J., Edwards, L. J., Hobson, P. J., Boto, E., Tierney, T. M., Rier, L., Rivero, G. R., et al. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120157 · Cited by 89
Self-citationNaturalistic Hyperscanning with Wearable Magnetoencephalography
Holmes, N., Rea, M., Hill, R. M., Boto, E., Leggett, J., Edwards, L. J., Rhodes, N., Shah, V., Osborne, J., Fromhold, T. M., et al. (2023) · Sensors · doi:10.3390/s23125454 · Cited by 52
“…mean OPM-MEG experiments involving participant motion not only require an MSR, but also ‘active’ magnetic shielding in the form of electromagnetic coils which cancel any residual magnetic field experienced by the array (Borna et al., 2020; Holmes et al., 2019, 2018; Iivanainen et al., 2019).”
BackgroundSelf-citationOptically Pumped Magnetometers for Practical MEG-Based Brain-Computer Interfacing
Wittevrongel, B., Holmes, N., Boto, E., Hill, R., Rea, M., Libert, A., Khachatryan, E., Bowtell, R., Brookes, M. J., & Van Hulle, M. M. (2021) · SpringerBriefs in Electrical and Computer Engineering · doi:10.1007/978-3-030-79287-9_4 · Cited by 9
Self-citation
Metadata
- Authors
- Holmes, N., Tierney, T. M., Leggett, J., Boto, E., Mellor, S., Roberts, G., Hill, R. M., Shah, V., Barnes, G. R., Brookes, M. J., & Bowtell, R.
- Affiliations
- University of Nottingham (GB)
- Wellcome Centre for Human Neuroimaging (GB)
- QuSpin (United States) (US)
- Corresponding author
- Bowtell, Richard
- ORCID
- Venue
- Scientific Reports
- Published
- 2019-10-02
- Volume
- 9
- Issue
- 1
- Pages
- 14196-14196
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC6775070
- OpenAlex
- W2978220154
- Cited by
- 163
- References
- 4
- Citations by year
- 2026: 15 · 2025: 45 · 2024: 33 · 2023: 23 · 2022: 22 · 2021: 17 · 2020: 8
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Scientific Reports (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Repository@Nottingham (University of Nottingham) (publishedVersion, other-oa)
- Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Funders
- Wellcome Trust (20357/B/16/Z, 203257/Z/16/Z)
- RCUK | Engineering and Physical Sciences Research Council (EP/M013294/1)
- U.S. Department of Health & Human Services | National Institutes of Health (R44HD074495, R44MH110288)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Keywords
- field compensation, magnetically shielded room, method of images, field uniformity, magnetic interference
- MeSH terms
- Wearable Electronic Devices, Equipment Design, Humans, Neurons, Magnetoencephalography, Physical Phenomena, Magnetic Fields
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review