Cited by 163Atomic and Subatomic Physics ResearchMagnetic Field Sensors TechniquesSuperconducting Materials and Applications

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Balanced, bi-planar magnetic field and field gradient coils for field compensation in wearable magnetoencephalography

Open access

Abstract

Abstract To allow wearable magnetoencephalography (MEG) recordings to be made on unconstrained subjects the spatially inhomogeneous remnant magnetic field inside the magnetically shielded room (MSR) must be nulled. Previously, a large bi-planar coil system which produces uniform fields and field gradients was used for this purpose. Its construction presented a significant challenge, six distinct coils were wound on two 1.6 × 1.6 m2 planes. Here, we exploit shared coil symmetries to produce coils simultaneously optimised to generate homogenous fields and gradients. We show nulling performance comparable to that of a six-coil system is achieved with this three-coil system, decreasing the strongest field component Bx by a factor of 53, and the strongest gradient dBx/dz by a factor of 7. To allow the coils to be used in environments with temporally-varying magnetic interference a dynamic nulling system was developed with a shielding factor of 40 dB at 0.01 Hz. Reducing the number of coils required and incorporating dynamic nulling should allow for greater take-up of this technology. Interactions of the coils with the high-permeability walls of the MSR were investigated using a method of images approach. Simulations show a degrading of field uniformity which was broadly consistent with measured values. These effects should be incorporated into future designs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-019-50697-w

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • OPM-MEG experiments involving participant motion require an OPM-optimised MSR with a very low remnant magnetic field and active magnetic shielding.

    “These constraints mean that OPM-MEG experiments involving participant motion require an OPM-optimised MSR with a very low remnant magnetic field along with ‘active’ magnetic shielding”

    From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [37]

    The Introduction (page unavailable) explains that motion can move OPMs outside their narrow operating range and that field-compensating coils enabled recordings during large participant movements. It also says dynamic compensation is required to address field drift. However, the paper describes using coils inside a two-layer magnetically shielded room; it does not establish that a specially OPM-optimised room is required. (LLM, conf=0.86)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 21

  1. Cohen, D. Magnetoencephalography: evidence of magnetic fields produced by alpha rhythm currents. Science 161, 784–786 (1968). · DOI · Paper page
  2. Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J. & Lounasmaa, O. V. Magnetoencephalography theory, instrumentation, and applications to noninvasive studies of the working human brain. Rev. Mod. Phys. 65, 413–497 (1993). · DOI · Paper page
  3. Witton, C., Furlong, P. L. & Seri, S. Technological challenges of pediatric MEG and potential solutions: The Aston experience. In Magnetoencephalography: From Signals to Dynamic Cortical Networks, https://doi.org/10.1007/978-3-642-33045-2_30 (2014). · DOI
  4. Borna, A. et al. A 20-channel magnetoencephalography system based on optically pumped magnetometers. Phys. Med. Biol. 62, 8909–8923 (2017). · DOI
  5. Shah, V. K. & Wakai, R. T. A compact, high performance atomic magnetometer for biomedical applications. Phys. Med. Biol. 58, 8153–8161 (2013). · DOI · Paper page
  6. Holmes, N. et al. A bi-planar coil system for nulling background magnetic fields in scalp mounted magnetoencephalography. Neuroimage, https://doi.org/10.1016/j.neuroimage.2018.07.028(2018). · DOI · Paper page
  7. Tierney, T. M. et al. Cognitive neuroscience using wearable magnetometer arrays: Non-invasive assessment of language function. Neuroimage 181, 513–520 (2018). · DOI
  8. Kastler, A. The Hanle effect and its use for the measurements of very small magnetic fields. Nucl. Instruments Methods 110, 259–265 (1973). · DOI
  9. Shah, V., Osborne, J., Orton, J. & Alem, O. Fully integrated, standalone zero field optically pumped magnetometer for biomagnetism. Steep Dispers. Eng. Opto-Atomic Precis. Metrol. X I 51, https://doi.org/10.1117/12.2299197 (2018). · DOI
  10. Iivanainen, J., Zetter, R., Grön, M., Hakkarainen, K. & Parkkonen, L. On-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers. Neuroimage, https://doi.org/10.1016/j.neuroimage.2019.03.022 (2019). · DOI · Paper page
  11. Moon, C. H., Park, H. W. & Lee, S. Y. A design method for minimum-inductance planar magnetic-resonance-imaging gradient coils considering the pole-piece effect. Meas. Sci. Technol. 10 (1999). · DOI
  12. Juhas, A., Pekari, N. & Toepfer, H. Magnetic Field of Rectangular Current Loop with Sides Parallel and Perpendicular to the Surface of High-permeability Material. 11, 701–717 (2014). · DOI
  13. Qinjie, C. et al. Optimization of a Coil System for Generating Uniform Magnetic Fields inside a Cubic. Energies 11, 608 (2018). · DOI
  14. Turner, R. Gradient coil design: A review of methods. Magnetic Resonance Imaging 11, 903–920 (1993). · DOI
  15. Carlson, J. W., Derby, K. A., Hawryszko, K. C. & Weideman, M. Design and evaluation of shielded gradient coils. Magn. Reson. Med. 26, 191–206 (1992). · DOI
  16. Yoda, K. Analytical design method of self-shielded planar coils. J. Appl. Phys. 67, 4349–4353 (1990). · DOI
  17. Dupont-Roc, J., Haroche, S. & Cohen-Tannoudji, C. Detection of very weak magnetic fields (10−9gauss) by 87Rb zero-field level crossing resonances. Phys. Lett. A 28, 638–639 (1969). · DOI
  18. Hoburg, J. F. Principles of Quasistatic Magnetic Shielding with Cylindrical and Spherical Shields. IEEE Transactions on Electromagnetic Compatibility, https://doi.org/10.1109/15.477342 (1995). · DOI
  19. Hammond, P. Electric and magnetic images. Proc. IEE Part C Monogr. 107, 306 (1960). · DOI
  20. Roshen, W. A. Effect of Finite Thickness of Magnetic Substrate on Planar Inductors. IEEE Trans. Magn. 26, 270–275 (1990). · DOI
  21. Martens, M. A. et al. Insertable biplanar gradient coils for magnetic resonance imaging. Rev. Sci. Instrum. 62, 2639–2645 (1991). · DOI

Cited by

Sorted by citations

Metadata

Authors
Holmes, N., Tierney, T. M., Leggett, J., Boto, E., Mellor, S., Roberts, G., Hill, R. M., Shah, V., Barnes, G. R., Brookes, M. J., & Bowtell, R.
Affiliations
  • University of Nottingham (GB)
  • Wellcome Centre for Human Neuroimaging (GB)
  • QuSpin (United States) (US)
Corresponding author
Bowtell, Richard
Venue
Scientific Reports
Published
2019-10-02
Volume
9
Issue
1
Pages
14196-14196
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2978220154
Cited by
163
References
4
Citations by year
2026: 15 · 2025: 45 · 2024: 33 · 2023: 23 · 2022: 22 · 2021: 17 · 2020: 8
FWCI
5.17
Type
journal article
Language
en
Open access
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Repository@Nottingham (University of Nottingham) (publishedVersion, other-oa)
  • Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • UCL Discovery (University College London) (submittedVersion)
Funders
  • Wellcome Trust (20357/B/16/Z, 203257/Z/16/Z)
  • RCUK | Engineering and Physical Sciences Research Council (EP/M013294/1)
  • U.S. Department of Health & Human Services | National Institutes of Health (R44HD074495, R44MH110288)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
Keywords
field compensation, magnetically shielded room, method of images, field uniformity, magnetic interference
MeSH terms
Wearable Electronic Devices, Equipment Design, Humans, Neurons, Magnetoencephalography, Physical Phenomena, Magnetic Fields

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review