Validation of 13c nmr measurement of human skeletal muscle glycogen by direct biochemical assay of needle biopsy samples
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Recent developments in 13 C nuclear magnetic resonance (NMR) spectroscopy have permitted noninvasive assessment of glycogen concentration in human skeletal muscle. Before these indirect measurements could be accepted as accurate, it was essential that validation should be carried out by comparing the widely used method of muscle biopsy and direct biochemical assay for glycogen concentration with measurement by NMR. Eight normal subjects underwent six NMR scans of gastrocnemius and three biopsies of the same muscle on the same day. The overall mean for muscle glycogen concentration was 87.4 m M by NMR and 88.3 m M by biopsy. There was a close correlation between the pairs of observations on each subject (R = 0.95; P 0.0001). The mean coefficient f variation for NMR measurement was 4.3 ± 2.1% and that for biopsy was 9.3 ± 5.9%. The performance of the muscle biopsies was accompanied by a small but significant rise in plasma‐free fatty acids (529 ± 157 to 667 ± 250; P < 0.01), epinephrine (17 ± 6 to 25 ± 8 pg/ml; P < 0.02), and norepinephrine (318 ± 119 to 400 ± 140 pg/ml; P < 0.02) but no change in plasma glucose, plasma insulin, nor muscle glycogen concentration assessed by NMR. The study demonstrates that in vivo 13 C NMR measurement of human muscle glycogen can be regarded as accurate, and the technique is associated with a higher precision than biopsy with direct biochemical assessment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Data on the distribution of fibre types in thirty-six human muscles
Johnson, M. A., Polgar, J., Weightman, D., & Appleton, D. (1973) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(73)90023-3 · Cited by 2,200
Shulman, G. I., Rothman, D. L., Jue, T., Stein, P., DeFronzo, R. A., & Shulman, R. G. (1990) · New England Journal of Medicine · doi:10.1056/nejm199001253220403 · Cited by 1,248
Self-citationCorrelation between muscle glycogen synthase activity and in vivo insulin action in man
Bogardus, C., Lillioja, S., Stone, K., & Mott, D. (1984) · Journal of Clinical Investigation · doi:10.1172/jci111304 · Cited by 335
Cited by
Mechanism of free fatty acid-induced insulin resistance in humans.
Roden, M., Price, T. B., Perseghin, G., Petersen, K. F., Rothman, D. L., Cline, G. W., & Shulman, G. I. (1996) · Journal of Clinical Investigation · doi:10.1172/jci118742 · Cited by 1,539
“The 13 C-NMR technique for assessing intramuscular glycogen concentrations has been validated by comparison with biopsied human gastrocnemius muscle tissue samples (25).”
MethodSelf-citationLipid-induced insulin resistance: unravelling the mechanism
Samuel, V. T., Petersen, K. F., & Shulman, G. I. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60408-4 · Cited by 1,189
Self-citationMRI detection of glycogen in vivo by using chemical exchange saturation transfer imaging (glycoCEST)
van Zijl, P. C. M., Jones, C. K., Ren, J., Malloy, C. R., & Sherry, A. D. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0700281104 · Cited by 420
Rothman, D. L., Magnusson, I., Cline, G., Gerard, D., Kahn, C. R., Shulman, R. G., & Shulman, G. I. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.4.983 · Cited by 325
Self-citationSteady‐State Cerebral Glucose Concentrations and Transport in the Human Brain
Gruetter, R., Ugurbil, K., & Seaquist, E. R. (1998) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.1998.70010397.x · Cited by 254
Liver glycogen metabolism during and after prolonged endurance-type exercise
Gonzalez, J. T., Fuchs, C. J., Betts, J. A., & van Loon, L. J. C. (2016) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00232.2016 · Cited by 206
Betts, J. A., & Williams, C. (2010) · Sports Medicine · doi:10.2165/11536900-000000000-00000 · Cited by 125
“employed (13)C-magnetic resonance spectroscopy to quantify glycogen in their study([71]) and, while this technique does correlate well with data acquired using the needle biopsy technique,([85]) it is impossible to determine whether the rates of muscle glycogen resynthesiswere indeed submaximal given that no absolute…”
Fuchs, C. J., Gonzalez, J. T., Beelen, M., Cermak, N. M., Smith, F. E., Thelwall, P. E., Taylor, R., Trenell, M. I., Stevenson, E. J., & van Loon, L. J. C. (2016) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01023.2015 · Cited by 56
Self-citationImpact of muscle glycogen availability on the capacity for repeated exercise in man
ALGHANNAM, A. F., JEDRZEJEWSKI, D., TWEDDLE, M. G., GRIBBLE, H., BILZON, J., THOMPSON, D., TSINTZAS, K., & BETTS, J. A. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000737 · Cited by 55
Muscle glycogen recovery after exercise during glucose and fructose intake monitored by13C-NMR
Van Den Bergh, A. J., Houtman, S., Heerschap, A., Rehrer, N. J., Van Den Boogert, H. J., Oeseburg, B., & Hopman, M. T. E. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.4.1495 · Cited by 30
Diurnal variation in the glycogen content of the human liver using 13C MRS
Iwayama, K., Onishi, T., Maruyama, K., & Takahashi, H. (2020) · NMR in Biomedicine · doi:10.1002/nbm.4289 · Cited by 24
“RF probe parameters (tuning, linewidth, and noise) did not change when switching from the subject's leg or liver to the phantom, verifying that the coil loading was constant.(14,23) To calibrate (13)C pulses, 1 M (13)C sodium acetate was used, positioned in the center of the surface coil.”
MethodBawden, S. J., Stephenson, M. C., Ciampi, E., Hunter, K., Marciani, L., Spiller, R. C., Aithal, G. P., Morris, P. G., Macdonald, I. A., & Gowland, P. A. (2014) · Food & Function · doi:10.1039/c4fo00050a · Cited by 10
Metadata
- Authors
- Taylor, R., Price, T. B., Rothman, D. L., Shulman, R. G., & Shulman, G. I.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1992-09
- Volume
- 27
- Issue
- 1
- Pages
- 13-20
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2109564986
- Cited by
- 113
- References
- 3
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.