The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
On the application of ultra‐fast rare experiments
Abstract
The ultra‐fast application of the RARE experiment is described in detail, with special emphasis on its multifarious applications with preparation experiments that produce transverse magnetization. The factors affecting the temporal evolution of the magnetization during the experiment are described, and the implications for the slice profile when using a Gaussian refocusing pulse are experimentally examined. The choice of phase‐encoding scheme for use with preparation experiments is discussed, as is the use of various phase‐encoding schemes to reduce line broadening in the phase‐encoding direction if a number of averages are acquired. An explanation for the decomposition of the echo are into two components if the read gradient is imbalanced is given, and the experimental conditions necessary for the coherent addition of these two echo groups are described. An alternative sequence that removes one of these groups from the acquisition window is proposed. The sensitivity of the sequence to flow and motion is investigated, and the drastic loss of signal in this situation explained. The in vivo and in vitro application of preparation experiments leading to the accurate measurement of T 1, T 2, diffusion constant, and magnetization transfer characteristics is presented. The implementation of zoom‐imaging using spin‐ and stimulated‐echo preparation is described, and 3D in vivo spin‐echo zoom images are presented. Simple phantom experiments demonstrating the feasibility of chemical‐shift selective and spectroscopic imaging are also given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Cited by
Niendorf, T., Dijkhuizen, R. M., Norris, D. G., van Lookeren Campagne, M., & Nicolay, K. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360607 · Cited by 570
Self-citationAn investigation of functional and anatomical connectivity using magnetic resonance imaging
Koch, M. A., Norris, D. G., & Hund-Georgiadis, M. (2002) · NeuroImage · doi:10.1006/nimg.2001.1052 · Cited by 509
Self-citationOptimized Single-Slab Three-dimensional Spin-Echo MR Imaging of the Brain
Mugler, J. P., Bao, S., Mulkern, R. V., Guttmann, C. R. G., Robertson, R. L., Jolesz, F. A., & Brookeman, J. R. (2000) · Radiology · doi:10.1148/radiology.216.3.r00au46891 · Cited by 334
Metadata
- Authors
- Norris, D. G., Börnert, P., Reese, T., & Leibfritz, D.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1992-09
- Volume
- 27
- Issue
- 1
- Pages
- 142-164
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2071556392
- Cited by
- 179
- References
- 1
- FWCI
- 6.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On the application of ultra‐fast rare experiments. https://app.cochat.ai/papers/10.1002/mrm.1910270114
- The paper
- Norris, D. G., Börnert, P., Reese, T., & Leibfritz, D. (1992). On the application of ultra‐fast rare experiments. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910270114
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.