The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Real‐time position monitoring of invasive devices using magnetic resonance
Abstract
Techniques which can be used to follow the position of invasive devices in real‐time using magnetic resonance (MR) are described. Tracking of an invasive device is made possible by incorporating one or more small RF coils into the device. These coils detect MR signals from only those spins near the coil. Pulse sequences which employ nonselective RF pulses to excite all nuclear spins within the field‐of‐view are used. Readout magnetic field gradient pulses, typically applied along one of the primary axes of the imaging system, are then used to frequency encode the position of the receive coil(s). Data are Fourier transformed and one or more peaks located to determine the position of each receiver coil in the direction of the applied field gradient. Subsequent data collected on orthogonal axes permits the localization of the receiver coil in three dimensions. The process can be repeated rapidly and the position of each coil can be displayed in real‐time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Encoding strategies for three‐direction phase‐contrast MR imaging of flow
Pelc, N. J., Bernstein, M. A., Shimakawa, A., & Glover, G. H. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010404 · Cited by 455
MR imaging of laser-tissue interactions.
Jolesz, F. A., Bleier, A. R., Jakab, P. D., Ruenzel, P., Hüttl, K., & Jako, G. J. (1988) · Radiology · doi:10.1148/radiology.168.1.3380968 · Cited by 327
Motion Artifact Suppression Technique (MAST) for MR Imaging
Pattany, P. M., Phillips, J. J., Chiu, L. C., Lipcamon, J. D., Duerk, J. L., McNally, J. M., & Mohapatra, S. N. (1987) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198705000-00001 · Cited by 217
Real‐time magnetic resonance imaging of laser heat deposition in tissue
Bleier, A. R., Jolesz, F. A., Cohen, M. S., Weisskoff, R. M., Dalcanton, J. J., Higuchi, N., Feinberg, D. A., Rosen, B. R., McKinstry, R. C., & Hushek, S. G. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910210116 · Cited by 150
NMR Even Echo Rephasing in Slow Laminar Flow
Waluch, V., & Bradley, W. G. (1984) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198408000-00003 · Cited by 146
Cited by
Prospective motion correction in brain imaging: A review
Maclaren, J., Herbst, M., Speck, O., & Zaitsev, M. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24314 · Cited by 401
On the heating of linear conductive structures as guide wires and catheters in interventional MRI
Nitz, W. R., Oppelt, A., Renz, W., Manke, C., Lenhart, M., & Link, J. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200101)13:1<105::aid-jmri1016>3.0.co;2-0 · Cited by 321
Real-Time Estimation of 3-D Needle Shape and Deflection for MRI-Guided Interventions
Park, Y.-L., Elayaperumal, S., Daniel, B., Ryu, S. C., Shin, M., Savall, J., Black, R. J., Moslehi, B., & Cutkosky, M. R. (2010) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2010.2080360 · Cited by 266
Nijsink, H., Overduin, C. G., Willems, L. H., Warlé, M. C., & Fütterer, J. J. (2022) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.28205 · Cited by 11
Metadata
- Authors
- Dumoulin, C. L., Souza, S. P., & Darrow, R. D.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1993-03
- Volume
- 29
- Issue
- 3
- Pages
- 411-415
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2030935958
- Cited by
- 445
- References
- 5
- FWCI
- 6.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real‐time position monitoring of invasive devices using magnetic resonance. https://app.cochat.ai/papers/10.1002/mrm.1910290322
- The paper
- Dumoulin, C. L., Souza, S. P., & Darrow, R. D. (1993). Real‐time position monitoring of invasive devices using magnetic resonance. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910290322
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.