The DOI matches its Crossref record.
Motion Artifact Suppression Technique (MAST) for MR Imaging
Abstract
A technique has been developed that significantly improves the image resolution and reduces motion artifacts in conventional two-dimensional Fourier transform and three-dimensional Fourier transform magnetic resonance imaging sequences. Modifications on the gradient waveforms completely refocus the transverse magnetization at the echo time, regardless of the motion occurring between the time of the 90 degrees radiofrequency excitation and the echo time (within-view). This accomplishes suppression of motion artifacts and regains the signal from flowing blood and CSF. Images of the head, abdomen, chest, and spine are reproduced which show the increase in signal and anatomical detail that would otherwise be degraded and lost in artifact noise. This technique has reduced the practical difficulty of obtaining clinically diagnostic T2-weighted abdominal images. It also has allowed diagnostic quality T1- and T2-weighted images to be obtained with one acquisition per view, thus reducing the total scan time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Frahm, J., Bruhn, H., Gyngell, M. L., Merboldt, K. D., Hänicke, W., & Sauter, R. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910090110 · Cited by 709
Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
Stehling, M. K., Turner, R., & Mansfield, P. (1991) · Science · doi:10.1126/science.1925560 · Cited by 623
Projection Reconstruction Techniques for Reduction of Motion Effects in MRI
Glover, G. H., & Pauly, J. M. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910280209 · Cited by 563
Real‐time position monitoring of invasive devices using magnetic resonance
Dumoulin, C. L., Souza, S. P., & Darrow, R. D. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290322 · Cited by 445
Metadata
- Authors
- Pattany, P. M., Phillips, J. J., Chiu, L. C., Lipcamon, J. D., Duerk, J. L., McNally, J. M., & Mohapatra, S. N.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1987-05
- Volume
- 11
- Issue
- 3
- Pages
- 369-377
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2016838404
- Cited by
- 217
- References
- 0
- FWCI
- 22.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Motion Artifact Suppression Technique (MAST) for MR Imaging. https://app.cochat.ai/papers/10.1097/00004728-198705000-00001
- The paper
- Pattany, P. M., Phillips, J. J., Chiu, L. C., Lipcamon, J. D., Duerk, J. L., McNally, J. M., & Mohapatra, S. N. (1987). Motion Artifact Suppression Technique (MAST) for MR Imaging. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-198705000-00001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.