Imaging time reduction through multiple receiver coil data acquisition and image reconstruction
The DOI matches its Crossref record.
Abstract
A technique is described for the simultaneous acquisition of MRI data using two independent receiver coils surrounding the same region of tissue, which enables the collection of data necessary for image reconstruction in a reduced number of phase‐encoded acquisitions. This results in a 50% reduction in minimum scan time and may be useful in time‐critical procedures. The algorithm and imaging procedures are described, and example images are shown that illustrate the reconstruction. Signal to noise is decreased by the square root of the time savings, making this technique applicable to cases in which the need to decrease minimum scan time outweighs the signal to noise penalty.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Partially parallel imaging with localized sensitivities (PILS)
Griswold, M. A., Jakob, P. M., Nittka, M., Goldfarb, J. W., & Haase, A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200010)44:4<602::aid-mrm14>3.0.co;2-5 · Cited by 329
Parallel magnetic resonance imaging
Larkman, D. J., & Nunes, R. G. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/7/r01 · Cited by 327
AUTO-SMASH: A self-calibrating technique for SMASH imaging
Jakob, P. M., Grisowld, M. A., Edelman, R. R., & Sodickson, D. K. (1998) · Magma: Magnetic Resonance Materials in Physics, Biology, and Medicine · doi:10.1007/bf02592256 · Cited by 278
WONDERLICK, J., ZIEGLER, D., HOSSEINIVARNAMKHASTI, P., LOCASCIO, J., BAKKOUR, A., VANDERKOUWE, A., TRIANTAFYLLOU, C., CORKIN, S., & DICKERSON, B. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.10.037 · Cited by 221
“The present study examined the effect of three elements of MRI data acquisition technology on the reliability of neuroanatomical measures: geometric reduction in voxel size (higher resolution), acceleration through parallel acquisition (Carlson and Minemura, 1993), and use of a high bandwidth, multiecho T1-weighted se…”
A brief review of parallel magnetic resonance imaging
Heidemann, R. M., �zsarlak, �., Parizel, P. M., Michiels, J., Kiefer, B., Jellus, V., M�ller, M., Breuer, F., Blaimer, M., Griswold, M. A., et al. (2003) · European Radiology · doi:10.1007/s00330-003-1992-7 · Cited by 190
“volume coil and one coil with a constant sensitivity gradient), was presented in 1993 [13].”
BackgroundImplications of SENSE MR in routine clinical practice
van den Brink, J. S., Watanabe, Y., Kuhl, C. K., Chung, T., Muthupillai, R., Van Cauteren, M., Yamada, K., Dymarkowski, S., Bogaert, J., Maki, J. H., et al. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00333-9 · Cited by 160
Linear inverse problems in imaging
Ribes, A., & Schmitt, F. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.923099 · Cited by 154
Metadata
- Authors
- Carlson, J. W., & Minemura, T.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1993-05
- Volume
- 29
- Issue
- 5
- Pages
- 681-687
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1986109830
- Cited by
- 120
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.