CoChat

Spin‐spin relaxation in experimental allergic Encephalomyelitis. Analysis of CPMG data using a non‐linear least squares method and linear inverse theory

Stewart, Wendy A., Mackay, Alex L., Whittall, Kenneth P., Moore, G. R. Wayne, Paty, Donald W. · 1993 · Magnetic Resonance in Medicine
Cited by 128

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

We have used the CPMG pulse sequence to measure proton T2 values and water content in spinal cord and brain samples from Hartley guinea pigs inoculated to produce experimental allergic encephalomyelitis (EAE). Relaxation data were fitted using minuit, a non‐linear curve fitting routine. Three exponentials provided the best fit to spinal cord data (10 ms (13%), 76 ms (57%), 215 ms (30%)) and two exponentials for brain tissue (10 ms (4%), 92 ms (96%)). Least squares algorithms were also used to analyse the spinal cord data in terms of discrete and smooth distributions of relaxation times. The discrete least squares solutions consisted of three to five isolated spikes between 0.010 and 0.300 s. This type of solution was difficult to interpret in terms of water reservoirs. Smooth solutions consisted of two broad peaks, a small peak with a T2 near 0.010 s and a larger peak near 0.100 s. The integral ratio of the larger to the smaller peak was 7.092 ± 1.782 for normal tissue, and increased to a maximum of 16 with increasing parenchymal cellular infiltration and demyelination. The short T2 peak has been assigned to water in the hydration layers of the myelin sheath. The width of the longer T2 peak was sensitive to tissue heterogeneity. The least squares and smooth distribution analysis models could be used to distinguish samples with extensive parenchymal infiltration from normal tissue, even though only a maximum of 60% of the tissue was affected. The short T2 component could provide a direct method of measuring intact myelin, which would have a profound effect on the understanding of the evolution of pathology in multiple sclerosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910290608

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 128

Metadata

Authors
Stewart, W. A., Mackay, A. L., Whittall, K. P., Moore, G. R. W., & Paty, D. W.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1993-06
Volume
29
Issue
6
Pages
767-775
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2097264258
Cited by
128
References
2
FWCI
3.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Spin‐spin relaxation in experimental allergic Encephalomyelitis. Analysis of CPMG data using a non‐linear least squares method and linear inverse theory. https://app.cochat.ai/papers/10.1002/mrm.1910290608
The paper
Stewart, W. A., Mackay, A. L., Whittall, K. P., Moore, G. R. W., & Paty, D. W. (1993). Spin‐spin relaxation in experimental allergic Encephalomyelitis. Analysis of CPMG data using a non‐linear least squares method and linear inverse theory. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910290608

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.