A diffusion‐weighted fast spin‐echo (FSE) imaging sequence for high‐field MR microscopy was developed and experimentally validated in a phantom and in a live rat. Pulsed diffusion gradients were executed before and after the initial 180° pulse in the FSE pulse train. This produced diffusion‐related reductions in image signal intensity corresponding to gradient (“b”) factors between 1.80 and 1352 s/mm 2. The degree of diffusion weighting was demonstrated to be independent of echo train length for experiments using trains up to 16 echoes long. Quantitative measurements on a phantom and on a live rat produced diffusion coefficients consistent with literature values. Importantly, the eight‐ to 16‐fold increase in imaging efficiency with FSE was not accompanied by a significant loss of spatial resolution or contrast. This permits acquisition of in vivo three‐dimensional data in time periods that are appropriate for evolving biological processes. The combination of accurate diffusion weighting and high spatial resolution provided by FSE makes the technique particularly useful for MR microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Cited by
Diffusion-weighted MR Imaging of the Brain
Schaefer, P. W., Grant, P. E., & Gonzalez, R. G. (2000) · Radiology · doi:10.1148/radiology.217.2.r00nv24331 · Cited by 1,052
Scollan, D. F., Holmes, A., Winslow, R., & Forder, J. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.275.6.h2308 · Cited by 457
State-of-the-Art Imaging of Acute Stroke
Srinivasan, A., Goyal, M., Azri, F. A., & Lum, C. (2006) · RadioGraphics · doi:10.1148/rg.26si065501 · Cited by 335
Diffusion Kurtosis Imaging maps neural damage in the EAE model of multiple sclerosis
Chuhutin, A., Hansen, B., Wlodarczyk, A., Owens, T., Shemesh, N., & Jespersen, S. N. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2019.116406 · Cited by 3
Metadata
- Authors
- Beaulieu, C. F., Zhou, X., Cofer, G. P., & Johnson, G. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1993-08
- Volume
- 30
- Issue
- 2
- Pages
- 201-206
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1993264220
- Cited by
- 50
- References
- 1
- FWCI
- 0.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.