Histological validation of myocardial microstructure obtained from diffusion tensor magnetic resonance imaging
Open accessAbstract
Diffusion tensor magnetic resonance imaging (MRI) is a possible new means of elucidating the anatomic structure of the myocardium. It enjoys several advantages over traditional histological approaches, including the ability to rapidly measure fiber organization in isolated, perfused, arrested hearts, thereby avoiding fixation and sectioning of artifacts. However, quantitative validation of this MRI method has been lacking. Here, fiber orientations estimated in the same locations in the same heart using both diffusion tensor MRI and histology are compared in a total of two perfused rabbit hearts. Fiber orientations were statistically similar for both methods and differed on average by 12° at any single location. This is similar to the 10° uncertainty in fiber orientation achieved with histology. In addition, imaging studies performed in a total of seven hearts support a level of organization beyond the myofiber, the recently described laminar organization of the ventricular myocardium.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Olivetti, G., Capasso, J. M., Sonnenblick, E. H., & Anversa, P. (1990) · Circulation Research · doi:10.1161/01.res.67.1.23 · Cited by 344
Cited by
Diffusion tensor imaging: Concepts and applications
Le Bihan, D., Mangin, J., Poupon, C., Clark, C. A., Pappata, S., Molko, N., & Chabriat, H. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1076 · Cited by 3,547
Bayer, J. D., Blake, R. C., Plank, G., & Trayanova, N. A. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0593-5 · Cited by 557
Nielles-Vallespin, S., Khalique, Z., Ferreira, P. F., de Silva, R., Scott, A. D., Kilner, P., McGill, L.-A., Giannakidis, A., Gatehouse, P. D., Ennis, D., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.11.051 · Cited by 267
Three-dimensional cardiac computational modelling: methods, features and applications.
Lopez-Perez, A., Sebastian, R., & Ferrero, J. M. (2015) · BioMedical Engineering OnLine · doi:10.1186/s12938-015-0033-5 · Cited by 151
Kaufman, J. A., Ahrens, E. T., Laidlaw, D. H., Zhang, S., & Allman, J. M. (2005) · The Anatomical Record Part A: Discoveries in Molecular, Cellular, and Evolutionary Biology · doi:10.1002/ar.a.20264 · Cited by 54
Metadata
- Authors
- Scollan, D. F., Holmes, A., Winslow, R., & Forder, J.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1998-12-01
- Volume
- 275
- Issue
- 6
- Pages
- H2308-H2318
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1934469715
- Cited by
- 457
- References
- 2
- FWCI
- 6.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Histological validation of myocardial microstructure obtained from diffusion tensor magnetic resonance imaging. https://app.cochat.ai/papers/10.1152/ajpheart.1998.275.6.h2308
- The paper
- Scollan, D. F., Holmes, A., Winslow, R., & Forder, J. (1998). Histological validation of myocardial microstructure obtained from diffusion tensor magnetic resonance imaging. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1998.275.6.h2308
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.