Novel approaches to low‐cost MRI
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper presents a combination of speculative approaches, some related to earlier work and some apparently novel, which show great promise in providing a new class of MRI machines that would be considerably less expensive. This class would have advantages and disadvantages as compared to existing MRI, over and above that of low cost. The disadvantages include the apparent inability to perform classic spectroscopy, and limited flexibility in the area of selective excitation. The advantages include a fundamental immunity to inhoinogenelty and susceptibility problems, the ability to create a wide class of machines that are designed for specific anatomy‐related applications, the ability to design open machines for physician access, and improved capability for high speed imaging. Generic to all of the methods presented are a pulsed polarizing field and an oscillatory readout bias field. The pulsed field initially polarizes the magnetic moments. Sinat it is not on during the readout operation it has negligible homogeneity requirements since changes in the field amplitude will merely shade the image intensity. During readout a relatively low bias field is used. To enable the use of a relatively inhomogeneous bias field, an osciliatory field is used that has a zero average value. This prevents any long‐term buildup of phase errors due to a frequency error associated with inhomogeneity. Thus the average bias frequency will be determined solely by the frequency rather than the amplitude of the bias field. Three methods are described, all including the above features. The first two involve imaging in the laboratory frame, while the third involves imaging in the rotating frame. The second approach requires no RF excitation and the third approach uses RF bias and gradient signals. Some approaches to slice selection are described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Romani, G. L., Williamson, S. J., & Kaufman, L. (1982) · Review of Scientific Instruments · doi:10.1063/1.1136907 · Cited by 235
Cited by
Sarracanie, M., LaPierre, C. D., Salameh, N., Waddington, D. E. J., Witzel, T., & Rosen, M. S. (2015) · Scientific Reports · doi:10.1038/srep15177 · Cited by 295
Wald, L. L., McDaniel, P. C., Witzel, T., Stockmann, J. P., & Cooley, C. Z. (2020) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26942 · Cited by 272
SQUID‐detected MRI at 132 μT with T1‐weighted contrast established at 10 μT–300 mT
Lee, S. K., Möβle, M., Myers, W., Kelso, N., Trabesinger, A. H., Pines, A., & Clarke, J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20316 · Cited by 139
Simultaneous magnetoencephalography and SQUID detected nuclear MR in microtesla magnetic fields
Volegov, P., Matlachov, A. N., Espy, M. A., George, J. S., & Kraus, R. H. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20193 · Cited by 80
SQUID-Detected in vivo MRI at Microtesla Magnetic Fields
Moszligle, M., Myers, W. R., Lee, S.-K., Kelso, N., Hatridge, M., Pines, A., & Clarke, J. (2005) · IEEE Transactions on Appiled Superconductivity · doi:10.1109/tasc.2005.850043 · Cited by 55
Metadata
- Authors
- Macovski, A., & Conolly, S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1993-08
- Volume
- 30
- Issue
- 2
- Pages
- 221-230
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1971395377
- Cited by
- 140
- References
- 1
- FWCI
- 2.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Novel approaches to low‐cost MRI. https://app.cochat.ai/papers/10.1002/mrm.1910300211
- The paper
- Macovski, A., & Conolly, S. (1993). Novel approaches to low‐cost MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910300211
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.