In Vivo proton spectroscopy and spectroscopic imaging of {1‐13C}‐g1ucose and its metabolic products
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Metaibolism of {1−13 C}‐glucose was studied in situ in cat brain usinig gradient‐enhanced proton‐detected heteronuclear spectroscopy. Proton detection of {1−13 C}‐glucose, {3−13 C}−lactaite, 4−{13 C}‐glutamine, 4−{13 C}‐glutamate and the combined signals 2−{13 C}‐glutamate/glutamine and 3−(13 C}‐glutamate/glutamine was achieved, despite the fact that some of the associated proton resonances are close to the water signal. Two‐dimensional {1 H‐13 C}‐spectra demonstrate the possibility of in situ spectral assignment with 1 H sensitivity and 13 C resolution. Spectroscopic images of glucose and its metabolic products were also acquired, showing the possibility to study spatial dependence of metabolism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The visibility of the 1H NMR signal of ethanol in the dog brain
Moxon, L. N., Rose, S. E., Haseler, L. J., Galloway, G. J., Brereton, I. M., Bore, P., & Doddrell, D. M. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910190225 · Cited by 26
Cited by
Keshari, K. R., & Wilson, D. M. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60124b · Cited by 358
Rothman, D. L., Behar, K. L., Hyder, F., & Shulman, R. G. (2003) · Annual Review of Physiology · doi:10.1146/annurev.physiol.65.092101.142131 · Cited by 337
State of the art direct 13 C and indirect 1 H‐[ 13 C] NMR spectroscopy in vivo . A practical guide
de Graaf, R. A., Rothman, D. L., & Behar, K. L. (2011) · NMR in Biomedicine · doi:10.1002/nbm.1761 · Cited by 117
Metadata
- Authors
- Van Zijl, P. C. M., Scott Chesnick, A., Despres, D., Moonen, C. T. W., Rhiz‐Cabello, J., & Van Gelderen, P.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1993-11
- Volume
- 30
- Issue
- 5
- Pages
- 544-551
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2012071052
- Cited by
- 99
- References
- 1
- FWCI
- 5.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In Vivo proton spectroscopy and spectroscopic imaging of {1‐13C}‐g1ucose and its metabolic products. https://app.cochat.ai/papers/10.1002/mrm.1910300504
- The paper
- Van Zijl, P. C. M., Scott Chesnick, A., Despres, D., Moonen, C. T. W., Rhiz‐Cabello, J., & Van Gelderen, P. (1993). In Vivo proton spectroscopy and spectroscopic imaging of {1‐13C}‐g1ucose and its metabolic products. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910300504
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.