Validation of 13C NMR measurements of liver glycogen in vivo
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The natural abundance 13 C NMR intensity of the glycogen C1 resonance was measured in the surgically exposed liver of rabbits in vivo (n = 17) by integration from 98 to 104 ppm and compared double blindedly to the subsequent biochemical measurement. Coil loading was measured each time from a reference sphere at the coil center and the NMR Intensity was normalized accordingly. For quantification, the normalized NMR intensity was calibrated using aqueous glycogen solutions ranging from 110 to 1100 μmol glucosyl units/g (n = 14). An in vivo range from 110 to 800 pmol glucosyl unit/g wet weight was measured with a highly linear correlation with concentration (r = 0.85, P < 0.001). The in vivo NMR concentration was 0.95 ± 0.05 (mean ± standard error, n = 17) of the concomitant enzymatic measurement of glycogen content. We conclude that the 13 C NMR signal of liver glycogen C1 is essentially 100% visible in vivo and that natural abundance 13 C NMR spectroscopy can provide reliable noninvasive estimates of in vivo glycogen content over the physiological range of liver glycogen concentrations when using adequate localization and Integration procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnusson, I., Rothman, D. L., Katz, L. D., Shulman, R. G., & Shulman, G. I. (1992) · Journal of Clinical Investigation · doi:10.1172/jci115997 · Cited by 757
Self-citationQuantitation of Hepatic Glycogenolysis And Gluconeogenesis in Fasting Humans With 13 C NMR
Rothman, D. L., Magnusson, I., Katz, L. D., Shulman, R. G., & Shulman, G. I. (1991) · Science · doi:10.1126/science.1948033 · Cited by 546
Self-citationNilsson, L. H., & Hultman, E. (1973) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365517309084355 · Cited by 263 · cited 1×
“, up to 620 pmol glucosy1 units/g wet weight (1, 21).”
Background
Cited by
Mechanism by which metformin reduces glucose production in type 2 diabetes.
Hundal, R. S., Krssak, M., Dufour, S., Laurent, D., Lebon, V, Chandramouli, V, Inzucchi, S. E., Schumann, W. C., Petersen, K. F., Landau, B. R., et al. (2000) · Diabetes · doi:10.2337/diabetes.49.12.2063 · Cited by 1,052
Self-citationContributions of gluconeogenesis to glucose production in the fasted state
Landau, B. R., Wahren, J., Chandramouli, V, Schumann, W. C., Ekberg, K., & Kalhan, S. C. (1996) · Journal of Clinical Investigation · doi:10.1172/jci118803 · Cited by 487
MRI detection of glycogen in vivo by using chemical exchange saturation transfer imaging (glycoCEST)
van Zijl, P. C. M., Jones, C. K., Ren, J., Malloy, C. R., & Sherry, A. D. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0700281104 · Cited by 420
Taylor, R., Magnusson, I., Rothman, D. L., Cline, G. W., Caumo, A., Cobelli, C., & Shulman, G. I. (1996) · Journal of Clinical Investigation · doi:10.1172/jci118379 · Cited by 258
“Nuclear magnetic resonance spectroscopy allows the direct, accurate, and repeated measurement of liver glycogen stores (14, 15).”
Self-citationSteady‐State Cerebral Glucose Concentrations and Transport in the Human Brain
Gruetter, R., Ugurbil, K., & Seaquist, E. R. (1998) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.1998.70010397.x · Cited by 254
Self-citation
Metadata
- Authors
- Gruetter, R., Magnusson, I., Rothman, D. L., Avison, M. J., Shulman, R. G., & Shulman, G. I.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1994-06
- Volume
- 31
- Issue
- 6
- Pages
- 583-588
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1896059842
- Cited by
- 69
- References
- 3
- FWCI
- 3.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.