Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 186

The DOI matches its Crossref record.

Evaluation of cerebral gray and white matter metabolite differences by spectroscopic imaging at 4.1T

Hetherington, Hoby P., Mason, Graeme F., Pan, Jullie W., Ponder, Steven L., Vaughan, J. Thomas, Twieg, Donald B., Pohost, Gerald M. · 1994 · Magnetic Resonance in Medicine

Abstract

Using a 4.1 T whole body system, we have acquired 1 H spectroscopic imaging (SI) data of N‐acetyl (NA) compounds, creatine (CR), and choline (CH) with nominal voxel sizes of 0.5 cc (1.15 cc after filtering). We have used the SI data to estimate differences in cerebral metabolites of human gray and white matter. To evaluate the origin of an increased CWNA and CWNA ratios in gray matter relative to white matter, we measured the T1 and T2 of CR, NA, and CH in gray and white matter using moderate resolution SI imaging. In white matter the T2 s of NA, CR, and CH were 233 ± 27,141 ± 18, and 167 ± 20 ms, respectively, and 227 ± 27,140 ± 16, and 189 ± 25 ms in gray matter. The T, values for NA, CR, and CH were 1267 ±141, 1487 ± 146, and 1111 ± 136 ms in gray matter and 1260 ± 154, 1429 & 233, and 1074 ± 146 ms in white matter. After correcting for T1 and T2 losses, creatine content was significantly lower in white matter than gray (P < e 0.01, t‐test), with a white/gray content ratio of 0.8, in agreement with biopsy and in vivo measurements at 1.5 and 2.0T.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910320504

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 186

Metadata

Authors
Hetherington, H. P., Mason, G. F., Pan, J. W., Ponder, S. L., Vaughan, J. T., Twieg, D. B., & Pohost, G. M.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1994-11
Volume
32
Issue
5
Pages
565-571
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2006464186
Cited by
186
References
0
FWCI
8.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of cerebral gray and white matter metabolite differences by spectroscopic imaging at 4.1T. https://app.cochat.ai/papers/10.1002/mrm.1910320504
The paper
Hetherington, H. P., Mason, G. F., Pan, J. W., Ponder, S. L., Vaughan, J. T., Twieg, D. B., & Pohost, G. M. (1994). Evaluation of cerebral gray and white matter metabolite differences by spectroscopic imaging at 4.1T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910320504

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.