Effect of Radio Frequency Inhomogeneity Correction on the Reproducibility of Intra‐Cranial Volumes Using MR Image Data
The DOI matches its Crossref record.
Abstract
The volumes of total brain, white matter, gray matter, and cerebrospinal fluid in normal volunteers were determined using a supervised nonparametric feature map segmentation of dual‐contrast MR images after correcting for the radio frequency (RF) inhomogeneity. Reproducibility of the segmentation was evaluated in terms of inter‐observer and scan‐to‐scan variations. A comparison with the published results indicates that the scan‐to‐scan and inter‐observer variabilities in the determination of tissue volumes are substantially reduced following the RF inhomogeneity correction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
Courchesne, E., Chisum, H. J., Townsend, J., Cowles, A., Covington, J., Egaas, B., Harwood, M., Hinds, S., & Press, G. A. (2000) · Radiology · doi:10.1148/radiology.216.3.r00au37672 · Cited by 1,049
A Review of Methods for Correction of Intensity Inhomogeneity in MRI
Vovk, U., Pernus, F., & Likar, B. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.891486 · Cited by 851
Automatic "pipeline" analysis of 3-D MRI data for clinical trials: application to multiple sclerosis
Zijdenbos, A. P., Forghani, R., & Evans, A. C. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.806283 · Cited by 761
Narayana, P. A., Doyle, T. J., Lai, D., & Wolinsky, J. S. (1998) · Annals of Neurology · doi:10.1002/ana.410430112 · Cited by 318
Self-citationA Review on MR Image Intensity Inhomogeneity Correction
Hou, Z. (2006) · International Journal of Biomedical Imaging · doi:10.1155/ijbi/2006/49515 · Cited by 200
A review of Methods for Bias Correction in Medical Images
Song, S., Zheng, Y., & He, Y. (2017) · Biomedical Engineering Review · doi:10.18103/bme.v3i1.1550 · Cited by 62
Normal brain volume measurements using multispectral MRI segmentation
Vaidyanathan, M., Clarke, L. P., Heidtman, C., Velthuizen, R. P., & Hall, L. O. (1997) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(96)00244-5 · Cited by 39
Metadata
- Authors
- Narayana, P. A., & Borthakur, A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1995-03
- Volume
- 33
- Issue
- 3
- Pages
- 396-400
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1998136038
- Cited by
- 64
- References
- 0
- FWCI
- 8.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.