The use of a priori knowledge to quantify short echo in vivo1h mr spectra
The DOI matches its Crossref record.
Abstract
In vivo 1 H MR spectra of the prefrontal cortex acquired with the stimulated echo acquisition mode (STEAM) TE = 20 ms sequence were quantified to determine relative levels of cerebral metabolites. A priori knowledge of spectra from individual metabolites in aqueous solution was incorporated into a frequency domain quantification technique. The accuracy and precision of modeling these metabolites were investigated with simulated spectra of varying signal‐to‐noise ratios (SNRs) and relative metabolite levels. The efficacy of modeling in vivo data was tested by quantifying 10 repeated measures of two consecutively acquired in vivo spectra (an 8−cm 3 volume of interest (VOI) and a 4−cm 3 VOI positioned within the 8−cm 3 VOI) on the same normal subject. The differences in levels of glutamate (Glu), phosphocreatine plus creatine (PCr+Cr) and choline‐containing compounds (Cho 1 between spectra from the 8− and 4−cm 3 VOIs corresponded with the expected differences observed in the proportions of gray matter within the VOIs (estimated from 1 H images). Correcting for the T1 and T2 relaxation, the estimated concentrations of N‐acetylaspartate, PCr+Cr, Cho 1, Glu, and glutamine were consistent with previous in vivo and in vitro reports.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lieberman, J. A., Perkins, D., Belger, A., Chakos, M., Jarskog, F., Boteva, K., & Gilmore, J. (2001) · Biological Psychiatry · doi:10.1016/s0006-3223(01)01303-8 · Cited by 593
Pfeuffer, J., Tkáč, I., Provencher, S. W., & Gruetter, R. (1999) · Journal of Magnetic Resonance · doi:10.1006/jmre.1999.1895 · Cited by 469
Time‐domain semi‐parametric estimation based on a metabolite basis set
Ratiney, H., Sdika, M., Coenradie, Y., Cavassila, S., Ormondt, D. V., & Graveron‐Demilly, D. (2005) · NMR in Biomedicine · doi:10.1002/nbm.895 · Cited by 295
Schubert, F., Gallinat, J., Seifert, F., & Rinneberg, H. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.11.014 · Cited by 282
Théberge, J., Al-Semaan, Y., Williamson, P. C., Menon, R. S., Neufeld, R. W. J., Rajakumar, N., Schaefer, B., Densmore, M., & Drost, D. J. (2003) · American Journal of Psychiatry · doi:10.1176/appi.ajp.160.12.2231 · Cited by 269
Self-citation
Metadata
- Authors
- Stanley, J. A., Drost, D. J., Williamson, P. C., & Terry Thompson, R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1995-07
- Volume
- 34
- Issue
- 1
- Pages
- 17-24
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2025133542
- Cited by
- 102
- References
- 0
- FWCI
- 6.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The use of a priori knowledge to quantify short echo in vivo1h mr spectra. https://app.cochat.ai/papers/10.1002/mrm.1910340105
- The paper
- Stanley, J. A., Drost, D. J., Williamson, P. C., & Terry Thompson, R. (1995). The use of a priori knowledge to quantify short echo in vivo1h mr spectra. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910340105
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.