High contrast and fast three‐dimensional magnetic resonance imaging at high fields

Lee, Jing‐Huei, Garwood, Michael, Menon, Ravi, Adriany, Gregor, Andersen, Peter, Truwit, Charles L., Uǧurbil, Kǎmil·1995·Magnetic Resonance in Medicine

Abstract

A new three‐dimensional imaging strategy based on magnetization prepared ultrafast gradient recalled echo technique that demonstrates pronounced T 1 contrast at high fields is introduced. High‐resolution three‐dimensional image sets of human brain showing high contrast between white and gray matter areas are presented. The ratio of contrast‐to‐noise was examined as a function of the relevant parameters in the imaging sequence; calculations based on high‐field T 1 values as well as the experimental data demonstrated that maximal contrast‐to‐noise ratio is attained under the same magnetization preparation conditions both for cortical and subcortical gray matter relative to white matter, leading to approximately equivalent appearance of all gray matter areas in the same image. In addition, the images displayed clear visualization of subtle anatomical structures such as the subthalamic nuclei (ventral tier nuclei, dorsomedial nucleus, and pulvinar) and mammillothalamic tracts.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910340305

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 225

Metadata

Authors
Lee, J., Garwood, M., Menon, R., Adriany, G., Andersen, P., Truwit, C. L., & Uǧurbil, K.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1995-09
Volume
34
Issue
3
Pages
308-312
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1984564555
Cited by
225
References
0
FWCI
4.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High contrast and fast three‐dimensional magnetic resonance imaging at high fields. https://app.cochat.ai/papers/10.1002/mrm.1910340305
The paper
Lee, J., Garwood, M., Menon, R., Adriany, G., Andersen, P., Truwit, C. L., & Uǧurbil, K. (1995). High contrast and fast three‐dimensional magnetic resonance imaging at high fields. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910340305

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.