The DOI matches its Crossref record.
High contrast and fast three‐dimensional magnetic resonance imaging at high fields
Abstract
A new three‐dimensional imaging strategy based on magnetization prepared ultrafast gradient recalled echo technique that demonstrates pronounced T 1 contrast at high fields is introduced. High‐resolution three‐dimensional image sets of human brain showing high contrast between white and gray matter areas are presented. The ratio of contrast‐to‐noise was examined as a function of the relevant parameters in the imaging sequence; calculations based on high‐field T 1 values as well as the experimental data demonstrated that maximal contrast‐to‐noise ratio is attained under the same magnetization preparation conditions both for cortical and subcortical gray matter relative to white matter, leading to approximately equivalent appearance of all gray matter areas in the same image. In addition, the images displayed clear visualization of subtle anatomical structures such as the subthalamic nuclei (ventral tier nuclei, dorsomedial nucleus, and pulvinar) and mammillothalamic tracts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Enhancement of MR Images Using Registration for Signal Averaging
Holmes, C. J., Hoge, R., Collins, L., Woods, R., Toga, A. W., & Evans, A. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199803000-00032 · Cited by 1,417
Functional imaging of the monkey brain
Logothetis, N. K., Guggenberger, H., Peled, S., & Pauls, J. (1999) · Nature Neuroscience · doi:10.1038/9210 · Cited by 540
fMRI evidence for dual routes to the mental lexicon in visual word recognition
Fiebach, C. J., Friederici, A. D., Müller, K., & Cramon, D. Y. V. (2002) · Journal of Cognitive Neuroscience · doi:10.1162/089892902317205285 · Cited by 518
Opitz, B., Rinne, T., Mecklinger, A., von Cramon, D. Y., & Schröger, E. (2002) · NeuroImage · doi:10.1006/nimg.2001.0970 · Cited by 514
The Anterior Frontomedian Cortex and Evaluative Judgment: An fMRI Study
Zysset, S., Huber, O., Ferstl, E., & von Cramon, D. Y. (2002) · NeuroImage · doi:10.1006/nimg.2001.1008 · Cited by 386
Metadata
- Authors
- Lee, J., Garwood, M., Menon, R., Adriany, G., Andersen, P., Truwit, C. L., & Uǧurbil, K.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1995-09
- Volume
- 34
- Issue
- 3
- Pages
- 308-312
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1984564555
- Cited by
- 225
- References
- 0
- FWCI
- 4.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High contrast and fast three‐dimensional magnetic resonance imaging at high fields. https://app.cochat.ai/papers/10.1002/mrm.1910340305
- The paper
- Lee, J., Garwood, M., Menon, R., Adriany, G., Andersen, P., Truwit, C. L., & Uǧurbil, K. (1995). High contrast and fast three‐dimensional magnetic resonance imaging at high fields. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910340305
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.