Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 170

The DOI matches its Crossref record.

Inhomogeneity correction using an estimated linear field map

Irarrazabal, Pablo, Meyer, Craig H., Nishimura, Dwight G., Macovski, Albert · 1996 · Magnetic Resonance in Medicine

Abstract

A fast and robust method for correcting magnetic resonance image distortion due to field in homogeneity is proposed and applied to spiral k‐space scanning. The method consists of acquiring a local field map, finding the best fit to a linear map, and using it to deblur the image distortions due to local frequency variations. The linear field map is determined using a maximum likelihood estimator with weights proportional to the pixel intensity. The method requires little additional computation and is robust in low signal regions and near abrupt field changes. Additionally. It can be used in combination with other deblurring methods. The application of this method is illustrated in conjunction with a mura'slice, T2‐weighted, breath‐held spiral scan of the liver.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910350221

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 170

Metadata

Authors
Irarrazabal, P., Meyer, C. H., Nishimura, D. G., & Macovski, A.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1996-02
Volume
35
Issue
2
Pages
278-282
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2063791807
Cited by
170
References
0
FWCI
9.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Inhomogeneity correction using an estimated linear field map. https://app.cochat.ai/papers/10.1002/mrm.1910350221
The paper
Irarrazabal, P., Meyer, C. H., Nishimura, D. G., & Macovski, A. (1996). Inhomogeneity correction using an estimated linear field map. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910350221

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.