Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 476

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Self‐navigated spiral fMRI: Interleaved versus single‐shot

Glover, Gary H., Lai, Song·1998·Magnetic Resonance in Medicine

Abstract

This study compares the measured activation volumes in motor cortex as well as the fluctuation noise and off‐resonance characteristics for 1‐, 2‐, and 4‐shot spiral gradient‐recalled echo blood oxygen level dependent contrast functional magnetic resonance imaging (fMRI) acquisitions, under conditions of constant resolution and scan time and with two readout durations. Reconstructions were made with and without self‐navigator correction. It was found that the navigator correction provided a 50% reduction in image fluctuation noise with 4‐shot acquisitions, and that multishot acquisitions perform as well as single‐shot techniques when self‐navigation is employed. An analysis of blurring showed that off‐resonance Af causes blurring when Δ f> 1/(2*Tad), where Tadis the readout duration. Off‐resonance effects were readily corrected during reconstruction with retrospective linear shim, even with the longer readout duration needed for single‐shot methods. With navigator and shim correction, single‐shot and multishot spiral methods are highly effective for fMRI acquisitions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910390305

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 476

Metadata

Authors
Glover, G. H., & Lai, S.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1998-03
Volume
39
Issue
3
Pages
361-368
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1971857019
Cited by
476
References
3
FWCI
29.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Self‐navigated spiral fMRI: Interleaved versus single‐shot. https://app.cochat.ai/papers/10.1002/mrm.1910390305
The paper
Glover, G. H., & Lai, S. (1998). Self‐navigated spiral fMRI: Interleaved versus single‐shot. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910390305

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.