Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 300

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Encoding of anisotropic diffusion with tetrahedral gradients: A general mathematical diffusion formalism and experimental results

Conturo, Thomas E., McKinstry, Robert C., Akbudak, Erbil, Robinson, Bruce H.·1996·Magnetic Resonance in Medicine

Abstract

A diffusion imaging method with a tetrahedral sampling pattern has been developed for high‐sensitivity diffusion analysis. The tetrahedral gradient pattern consists of four different combinations of x, y, and z gradients applied simultaneously at full strength to uniformly measure diffusion in four different directions. Signal‐to‐noise can be increased by up to a factor of about three using this approach, compared with diffusion measurements made using separately applied x, y, and z gradients. A mathematical formalism is presented describing six fundamental parameters: the directionally averaged diffusion coefficient D and diffusion element anisotropies η and ε which are rotationally invariant, and diffusion ellipsoid orientation angles θ, ϕ, and Ψ which are rotationally variant. These six parameters contain all the information in the symmetric diffusion tensor D. Principal diffusion coefficients, reduced anisotropies, and other rotational invariants are further defined. It is shown that measurement of off‐diagonal tensor elements is essential to assess anisotropy and orientation, and that the only parameter which can be measured with the orthogonal method is D. In cases of axial diffusion symmetry (e.g., fibers), the four tetrahedral diffusion measurements efficiently enable determination of D, η, θ, and ϕ which contain all the diffusion information. From these four parameters, the diffusion parallel and perpendicular to the symmetry axis (D 1 and D 1) and the axial anisotropy A can be determined. In more general cases, the six fundamental parameters can be determined with two additional diffusion measurements. Tetrahedral diffusion sequences were implemented on a clinical MR system. A muscle phantom demonstrates orientation independence of D, D1, D1, and A for large changes in orientation angles. Sample background gradients and diffusion gradient imbalances were directly measured and found to be insignificant in most cases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910350319

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 300

Metadata

Authors
Conturo, T. E., McKinstry, R. C., Akbudak, E., & Robinson, B. H.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1996-03
Volume
35
Issue
3
Pages
399-412
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2049965228
Cited by
300
References
1
FWCI
12.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Encoding of anisotropic diffusion with tetrahedral gradients: A general mathematical diffusion formalism and experimental results. https://app.cochat.ai/papers/10.1002/mrm.1910350319
The paper
Conturo, T. E., McKinstry, R. C., Akbudak, E., & Robinson, B. H. (1996). Encoding of anisotropic diffusion with tetrahedral gradients: A general mathematical diffusion formalism and experimental results. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910350319

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.