The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Diffusion‐weighted interleaved echo‐planar imaging with a pair of orthogonal navigator echoes
Abstract
This work describes a diffusion‐weighted (DW) interleaved echo‐planar imaging (IEPI) method for use on either conventional whole‐body scanners or scanners equipped with highspeed gradient and receiver hardware. In combination with cardiac gating and motion correction with a pair of orthogonal navigator echoes, the presented method is time‐efficient, compensates for patient motions, and is less sensitive to image distortions than single‐shot methods. The motion‐correction scheme consists of correction for constant and linear phase terms found from the orthogonal navigator echoes. The correction for the linear phase term in the phase‐encode direction includes gridding the data to the Cartesian grid. The DW IEPI was used to image a phantom rotating about the slice‐select direction, and motion correction was performed to eliminate ghost artifacts arising from motion in either the readout‐ or phase‐encoding directions. DW IEPI with motion correction was performed on a normal volunteer and on a patient with a 26‐day‐old region of ischemia over much of the right hemisphere.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Cited by
White matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
Diffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Basic principles of diffusion-weighted imaging
Bammer, R. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00303-0 · Cited by 851
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Chen, N.-K., Guidon, A., Chang, H.-C., & Song, A. W. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.01.038 · Cited by 364
Metadata
- Authors
- Butts, K., de Crespigny, A., Pauly, J. M., & Moseley, M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1996-05
- Volume
- 35
- Issue
- 5
- Pages
- 763-770
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2093712031
- Cited by
- 244
- References
- 1
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diffusion‐weighted interleaved echo‐planar imaging with a pair of orthogonal navigator echoes. https://app.cochat.ai/papers/10.1002/mrm.1910350518
- The paper
- Butts, K., de Crespigny, A., Pauly, J. M., & Moseley, M. (1996). Diffusion‐weighted interleaved echo‐planar imaging with a pair of orthogonal navigator echoes. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910350518
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.