Observation of resolved glucose signals in 1H NMR spectra of the human brain at 4 Tesla
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Measurement of the resonances of glucose between 3.2 and 3.9 ppm in 1 H NMR spectra from the human brain is difficult due to spectral overlap with peaks from more concentrated metabolites. The H1 resonance of α‐D‐glucose at 5.23 ppm is resolved from other metabolite peaks, but potentially overlaps with the intense water signal at 4.72 ppm. This paper demonstrates that the increased resolution at 4 Tesla permits to suppress the water signal sufficiently to reliably detect glucose directly at 5.23 ppm by 1 H MRS and the estimated peak intensity is consistent with previous 13 C NMR quantification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reduced Glucose Transporter at the Blood‐Brain Barrier and in Cerebral Cortex in Alzheimer Disease
Kalaria, R. N., & Harik, S. I. (1989) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1989.tb07399.x · Cited by 338 · cited 1×
“Glucose transport has been suggested to increase in chronic hypoglycemia and seizures and to decrease in chronic hyperglycemia and Alzheimer's disease (7-9).”
Cited by
Proton NMR chemical shifts and coupling constants for brain metabolites
Govindaraju, V., Young, K., & Maudsley, A. A. (2000) · NMR in Biomedicine · doi:10.1002/1099-1492(200005)13:3<129::aid-nbm619>3.0.co;2-v · Cited by 1,689
Simultaneousin vivo spectral editing and water suppression
Mescher, M., Merkle, H., Kirsch, J., Garwood, M., & Gruetter, R. (1998) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199810)11:6<266::aid-nbm530>3.0.co;2-j · Cited by 1,015
Self-citationIn vivo1H NMR spectroscopy of rat brain at 1 ms echo time
Tk�?, I., Star?uk, Z., Choi, I.-Y., & Gruetter, R. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199904)41:4<649::aid-mrm2>3.0.co;2-g · Cited by 1,005
Self-citation7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890
Self-citationPfeuffer, J., Tkáč, I., Provencher, S. W., & Gruetter, R. (1999) · Journal of Magnetic Resonance · doi:10.1006/jmre.1999.1895 · Cited by 469
Self-citation
Metadata
- Authors
- Gruetter, R., Garwood, M., Uǧurbil, K., & Seaquist, E. R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1996-07
- Volume
- 36
- Issue
- 1
- Pages
- 1-6
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1976959012
- Cited by
- 93
- References
- 1
- FWCI
- 7.60
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Observation of resolved glucose signals in 1H NMR spectra of the human brain at 4 Tesla. https://app.cochat.ai/papers/10.1002/mrm.1910360102
- The paper
- Gruetter, R., Garwood, M., Uǧurbil, K., & Seaquist, E. R. (1996). Observation of resolved glucose signals in 1H NMR spectra of the human brain at 4 Tesla. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910360102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.