The DOI matches its Crossref record.
Time‐resolved contrast‐enhanced 3D MR angiography
Abstract
An MR angiographic technique, referred to as 3D TRICKS (3D time‐resolved imaging of contrast kinetics) has been developed. This technique combines and extends to 3D imaging several previously published elements. These elements include an increased sampling rate for lower spatial frequencies, temporal interpolation of k‐space views, and zero‐filling in the slice‐encoding dimension. When appropriately combined, these elements permit reconstruction of a series of 3D image sets having an effective temporal frame rate of one volume every 2‐6 s. Acquiring a temporal series of images offers advantages over the current contrast‐enhanced 3D MRA techniques in that it i) increases the likelihood that an arterial‐only 3D image set will be obtained, ii) permits the passage of the contrast agent to be observed, and iii) allows temporal‐processing techniques to be applied to yield additional information, or improve image quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Lustig, M., Donoho, D. L., Santos, J. M., & Pauly, J. M. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914728 · Cited by 2,246
25 Years of Contrast-Enhanced MRI: Developments, Current Challenges and Future Perspectives
Lohrke, J., Frenzel, T., Endrikat, J., Alves, F. C., Grist, T. M., Law, M., Lee, J. M., Leiner, T., Li, K.-C., Nikolaou, K., et al. (2016) · Advances in Therapy · doi:10.1007/s12325-015-0275-4 · Cited by 420
Self-citationUndersampled projection reconstruction applied to MR angiography
Peters, D. C., Korosec, F. R., Grist, T. M., Block, W. F., Holden, J. E., Vigen, K. K., & Mistretta, C. A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200001)43:1<91::aid-mrm11>3.0.co;2-4 · Cited by 375
Self-citationBarger, A. V., Block, W. F., Toropov, Y., Grist, T. M., & Mistretta, C. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10212 · Cited by 291
Self-citation
Metadata
- Authors
- Korosec, F. R., Frayne, R., Grist, T. M., & Mistretta, C. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1996-09
- Volume
- 36
- Issue
- 3
- Pages
- 345-351
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2171752072
- Cited by
- 877
- References
- 0
- FWCI
- 40.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Time‐resolved contrast‐enhanced 3D MR angiography. https://app.cochat.ai/papers/10.1002/mrm.1910360304
- The paper
- Korosec, F. R., Frayne, R., Grist, T. M., & Mistretta, C. A. (1996). Time‐resolved contrast‐enhanced 3D MR angiography. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910360304
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.