The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Time‐resolved contrast‐enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory
Abstract
Time‐resolved contrast‐enhanced 3D MR angiography (MRA) methods have gained in popularity but are still limited by the tradeoff between spatial and temporal resolution. A method is presented that greatly reduces this tradeoff by employing undersampled 3D projection reconstruction trajectories. The variable density k‐space sampling intrinsic to this sequence is combined with temporal k‐space interpolation to provide time frames as short as 4 s. This time resolution reduces the need for exact contrast timing while also providing dynamic information. Spatial resolution is determined primarily by the projection readout resolution and is thus isotropic across the FOV, which is also isotropic. Although undersampling the outer regions of k‐space introduces aliased energy into the image, which may compromise resolution, this is not a limiting factor in high‐contrast applications such as MRA. Results from phantom and volunteer studies are presented demonstrating isotropic resolution, broad coverage with an isotropic field of view (FOV), minimal projection reconstruction artifacts, and temporal information. In one application, a single breath‐hold exam covering the entire pulmonary vasculature generates high‐resolution, isotropic imaging volumes depicting the bolus passage. Magn Reson Med 48:297–305, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jackson, J. I., Meyer, C. H., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.97598 · Cited by 1,059
Time‐resolved contrast‐enhanced 3D MR angiography
Korosec, F. R., Frayne, R., Grist, T. M., & Mistretta, C. A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360304 · Cited by 877
Self-citationProjection Reconstruction Techniques for Reduction of Motion Effects in MRI
Glover, G. H., & Pauly, J. M. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910280209 · Cited by 563
Homodyne detection in magnetic resonance imaging
Noll, D. C., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.79473 · Cited by 514
Undersampled projection reconstruction applied to MR angiography
Peters, D. C., Korosec, F. R., Grist, T. M., Block, W. F., Holden, J. E., Vigen, K. K., & Mistretta, C. A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200001)43:1<91::aid-mrm11>3.0.co;2-4 · Cited by 375
Self-citationMR fluoroscopy: Technical feasibility
Riederer, S. J., Tasciyan, T., Farzaneh, F., Lee, J. N., Wright, R. C., & Herfkens, R. J. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910080102 · Cited by 370
Reduced aliasing artifacts using variable-densityk-space sampling trajectories
Tsai, C.-M., & Nishimura, D. G. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200003)43:3<452::aid-mrm18>3.0.co;2-b · Cited by 237
Boron‐11 imaging with a three‐dimensional reconstruction method
Glover, G. H., Pauly, J. M., & Bradshaw, K. M. (1992) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880020109 · Cited by 131
Effects of polar sampling in k‐space
Lauzon, M. L., & Rutt, B. K. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360617 · Cited by 105
Dynamic 3D MR angiography of the pulmonary arteries in under four seconds
Goyen, M., Laub, G. A., Ladd, M. E., et al. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1053 · Cited by 103
Cited by
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577
Johansson, A., Karlsson, M., & Nyholm, T. (2011) · Medical Physics · doi:10.1118/1.3578928 · Cited by 324
Optimized 3D ultrashort echo time pulmonary MRI
Johnson, K. M., Fain, S. B., Schiebler, M. L., & Nagle, S. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24570 · Cited by 322
Perfusion Imaging of the Liver: Current Challenges and Future Goals
Pandharipande, P. V., Krinsky, G. A., Rusinek, H., & Lee, V. S. (2005) · Radiology · doi:10.1148/radiol.2343031362 · Cited by 294
Metadata
- Authors
- Barger, A. V., Block, W. F., Toropov, Y., Grist, T. M., & Mistretta, C. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-07-31
- Volume
- 48
- Issue
- 2
- Pages
- 297-305
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2011721142
- Cited by
- 291
- References
- 12
- FWCI
- 12.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Time‐resolved contrast‐enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory. https://app.cochat.ai/papers/10.1002/mrm.10212
- The paper
- Barger, A. V., Block, W. F., Toropov, Y., Grist, T. M., & Mistretta, C. A. (2002). Time‐resolved contrast‐enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10212
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.