Dynamic MR digital subtraction angiography using contrast enhancement, fast data acquisition, and complex subtraction
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A dynamic MR angiography technique, MR digital subtraction angiography (MR DSA), is proposed using fast acquisition, contrast enhancement, and complex subtraction. When a bolus of contrast is injected into a patient, data acquisition begins, dynamically acquiring a thick slab using a fast gradient echo sequence for 10–100 s. Similar to x‐ray DSA, a mask is selected from the images without contrast enhancement, and later images are subtracted from the mask to generate angiograms. Complex subtraction is used to overcome the partial volume effects related to the phase difference between the flowing and stationary magnetization in a voxel. Vessel signal is the enhancement of flow magnetization resulting from the contrast bolus. MR DSA was performed in 28 patients, including vessels in the lungs, brains, legs, abdomen, and pelvis. All targeted vessels were well depicted with MR DSA. Corresponding dynamic information (contrast arrival time t a and duration of the arterial phase t av) was measured: t a/t av = 3.4/4.7 s for the lung, 10.3/4.9 s for the brain, 12.8/19.3 for the aorta, 15.2/12.6 s for the leg. MR DSA can provide dynamic angiographic images using a very short acquisition time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gadolinium-enhanced MR aortography.
Prince, M. R. (1994) · Radiology · doi:10.1148/radiology.191.1.8134563 · Cited by 884 · cited 3×
“To optimize the MR signal at the bolus peak in our experiments, we chose 45” as the flip angle, which is consistent with the literature (3).”
BackgroundMethodInfluentialMagnetic resonance angiography.
Dumoulin, C. L., & Hart, H. R. (1986) · Radiology · doi:10.1148/radiology.161.3.3786721 · Cited by 506
gadolinium-enchanced MR aortography.
Kumar, P. (1994) · Radiology · Cited by 495
Projection angiograms of blood labeled by adiabatic fast passage
Dixon, W. T., Du, L. N., Faul, D. D., Gado, M., & Rossnick, S. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030311 · Cited by 282
MR angiography by selective inversion recovery
Nishimura, D. G., Macovski, A., Pauly, J. M., & Conolly, S. M. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910040214 · Cited by 171 · cited 1×
“Thick slab is used to cover the anatomy of interest (6-9).”
Method
Cited by
Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Self-citation
Metadata
- Authors
- Wang, Y., Johnston, D. L., Breen, J. F., Iii, J. H., Jack, C. R., Julsrud, P. R., Kiely, M. J., King, B. F., Riederer, S. L., & Ehman, R. L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1996-10
- Volume
- 36
- Issue
- 4
- Pages
- 551-556
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2139376315
- Cited by
- 162
- References
- 5
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic MR digital subtraction angiography using contrast enhancement, fast data acquisition, and complex subtraction. https://app.cochat.ai/papers/10.1002/mrm.1910360408
- The paper
- Wang, Y., Johnston, D. L., Breen, J. F., Iii, J. H., Jack, C. R., Julsrud, P. R., Kiely, M. J., King, B. F., Riederer, S. L., & Ehman, R. L. (1996). Dynamic MR digital subtraction angiography using contrast enhancement, fast data acquisition, and complex subtraction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910360408
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.