The DOI matches its Crossref record.
Gadolinium-enhanced MR aortography.
Abstract
PURPOSE: To evaluate the potential for preferential arterial enhancement at magnetic resonance (MR) aortography with an intravenous infusion of paramagnetic contrast material. MATERIALS AND METHODS: Gadolinium chelates were administered intravenously (0.2 mmol/kg) during three-dimensional MR imaging (1.5 T) in 125 patients (77 male and 48 female patients, aged 4-86 years [mean, 66 years]) with suspected aorta or aortic branch vessel disease. RESULTS: Infusion for the duration of the MR acquisition resulted in significant preferential arterial enhancement without the confounding effects of excessive venous or background-tissue enhancement (P < 10(-5)). Angiographic or surgical correlation in 48 patients revealed an 88% sensitivity and a 97% specificity for detection of stenoses or occlusions and a 100% sensitivity and a 100% specificity for detection of aortic or iliac artery aneurysms. CONCLUSION: Preferential arterial enhancement is possible at MR aortography with an intravenous infusion of paramagnetic contrast material.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ruehm, S. G., Corot, C., Vogt, P., Kolb, S., & Debatin, J. F. (2001) · Circulation · doi:10.1161/01.cir.103.3.415 · Cited by 599
Burrel, M., Llovet, J. M., Ayuso, C., Iglesias, C., Sala, M., Miquel, R., Caralt, T., Ayuso, J. R., Solé, M., Sanchez, M., et al. (2003) · Hepatology · doi:10.1002/hep.1840380430 · Cited by 451
25 Years of Contrast-Enhanced MRI: Developments, Current Challenges and Future Perspectives
Lohrke, J., Frenzel, T., Endrikat, J., Alves, F. C., Grist, T. M., Law, M., Lee, J. M., Leiner, T., Li, K.-C., Nikolaou, K., et al. (2016) · Advances in Therapy · doi:10.1007/s12325-015-0275-4 · Cited by 420
Self-citationNephrotoxicity of high‐dose gadolinium compared with iodinated contrast
Prince, M. R., Arnoldus, C., & Frisoli, J. K. (1996) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880060129 · Cited by 398
Self-citationMR Pulse Sequences: What Every Radiologist Wants to Know but Is Afraid to Ask
Bitar, R., Leung, G., Perng, R., Tadros, S., Moody, A. R., Sarrazin, J., McGregor, C., Christakis, M., Symons, S., Nelson, A., et al. (2006) · RadioGraphics · doi:10.1148/rg.262055063 · Cited by 383
Metadata
- Authors
- Prince, M. R.
- Venue
- Radiology
- Published
- 1994-04
- Volume
- 191
- Issue
- 1
- Pages
- 155-164
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2111350768
- Cited by
- 884
- References
- 0
- FWCI
- 40.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gadolinium-enhanced MR aortography. https://app.cochat.ai/papers/10.1148/radiology.191.1.8134563
- The paper
- Prince, M. R. (1994). Gadolinium-enhanced MR aortography. Radiology. https://doi.org/10.1148/radiology.191.1.8134563
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.