CoChat

Broadband decoupled, 1H‐localized 13C MRS of the human brain at 4 tesla

Open access
Gruetter, Rolf, Adriany, Gregor, Merkle, Hellmut, Andersen, Peter M. · 1996 · Magnetic Resonance in Medicine
Cited by 75

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Broadband proton decoupling of the entire 13 C spectrum was possible within power absorption guidelines and resulted in the detection of narrow (as low as 2–3 Hz), natural abundance signals from metabolites such as myo‐inositol, glutamate, N‐acetyl‐aspartate, and glutamine from 72 cm 3 volumes in the human brain. To overcome the chemical shift displacement error, three‐dimensional localization on the 1 H z magnetization was combined with polarization transfer. Efficiency of the heteronuclear localization method was demonstrated by the elimination of all scalp lipid resonances. A signal‐to‐noise ratio of 5:1 for 0.07 m M [13 C] was achieved in 12 min, which is approximately a fivefold improvement over the sensitivity reported at 2.1 Tesla.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910360503

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 75

Metadata

Authors
Gruetter, R., Adriany, G., Merkle, H., & Andersen, P. M.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1996-11
Volume
36
Issue
5
Pages
659-664
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2061811871
Cited by
75
References
1
FWCI
6.80
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.