The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Magnetic resonance spectroscopy of the human brain
Open accessAbstract
Magnetic resonance (MR; synonymous with NMR = nuclear magnetic resonance) is a universal physical technique best known for non‐invasive detection and anatomical mapping of water protons (H). MR‐spectroscopy (MRS) records protons from tissue chemicals other than water, intrinsic phosphorus containing metabolites, sodium, potassium, carbon, nitrogen, and fluorine. MRS is therefore an imaging technique with the potential to record human and animal biochemistry in vivo. As a result of wide availability of MRI equipment in research laboratories and hospitals, MRS is a serious competitor with PET to define normal body composition and its perturbation by pharmacological and pathological events. This article describes practical aspects of in vivo MRS with particular emphasis on the brain, where novel metabolites have been described. A survey of these new aspects of neurochemistry emphasize their practical utility as neuronal and axonal markers, measures of energy status, membrane constituents, and osmolytes, as well as some xenobiotics, such as alcohol. The concept of multinuclear in vivo MRS is illustrated by diagnosis and therapeutic monitoring of several human brain disorders. Although these methods are currently most frequently encountered in human studies, as well as with transgenic and knockout mouse models, MRS adds a new dimension to anatomic and histopathologic descriptions. Anat Rec (New Anat) 265:54–84, 2001. © 2001 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Viability thresholds and the penumbra of focal ischemia
Hossmann, K. (1994) · Annals of Neurology · doi:10.1002/ana.410360404 · Cited by 1,370
Cited by
Neuroimaging creativity: a psychometric view
Arden, R., Chavez, R. S., Grazioplene, R., & Jung, R. E. (2010) · Behavioural Brain Research · doi:10.1016/j.bbr.2010.05.015 · Cited by 287
Gigante, A. D., Bond, D. J., Lafer, B., Lam, R. W., Young, L. T., & Yatham, L. N. (2012) · Bipolar Disorders · doi:10.1111/j.1399-5618.2012.01033.x · Cited by 226
Body mass index and magnetic resonance markers of brain integrity in adults
Gazdzinski, S., Kornak, J., Weiner, M. W., & Meyerhoff, D. J. (2008) · Annals of Neurology · doi:10.1002/ana.21377 · Cited by 191
Meyerhoff, D. J., Mon, A., Metzler, T., & Neylan, T. C. (2014) · Sleep · doi:10.5665/sleep.3654 · Cited by 133
Maturation of the human fetal brain as observed by 1H MR spectroscopy
Kok, R. D., van den Berg, P. P., van den Bergh, A. J., Nijland, R., & Heerschap, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10264 · Cited by 129
Metadata
- Authors
- Ross, B., & Bluml, S.
- Venue
- The Anatomical Record
- Publisher
- Wiley
- Published
- 2001-04-15
- Volume
- 265
- Issue
- 2
- Pages
- 54-84
- ISSN
- 0003-276X (ISSN-L)
- 1097-0185
- OpenAlex
- W2023630108
- Cited by
- 411
- References
- 1
- FWCI
- 10.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic resonance spectroscopy of the human brain. https://app.cochat.ai/papers/10.1002/ar.1058
- The paper
- Ross, B., & Bluml, S. (2001). Magnetic resonance spectroscopy of the human brain. The Anatomical Record. https://doi.org/10.1002/ar.1058
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.