Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 198

The DOI matches its Crossref record.

Optimization of spoiled gradient‐echo phase imaging for in vivo localization of a focused ultrasound beam

Chung, Andrew H., Hynynen, Kullervo, Colucci, Vincent, Oshio, Koichi, Cline, Harvey E., Jolesz, Ferenc A.·1996·Magnetic Resonance in Medicine

Abstract

The parameters of a spoiled gradient‐echo (SPGR) pulse sequence have been optimized for in vivo localization of a focused ultrasound beam. Temperature elevation was measured by using the proton resonance frequency shift technique, and the phase difference signal‐to‐noise ratio (SNR δ ϕ) was estimated in skeletal muscle and kidney cortex in 10 rabbits. Optimized parameters included the echo time equivalent to T*2 of the tissue, the longest repetition time possible with a 20‐s sonication, and the flip angle equivalent to the Ernst angle. Optimal SPGR phase imaging can detect a sonication beam with a peak phase difference of 0.55 radian, which corresponds to a temperature elevation of 7.3°C. The sonication beam can be localized within one voxel (0.6 × 0.6 × 5 mm 3) at power levels that are below the threshold for thermal damage of the tissue.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910360513

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 198

Metadata

Authors
Chung, A. H., Hynynen, K., Colucci, V., Oshio, K., Cline, H. E., & Jolesz, F. A.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1996-11
Volume
36
Issue
5
Pages
745-752
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2157277469
Cited by
198
References
0
FWCI
14.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optimization of spoiled gradient‐echo phase imaging for in vivo localization of a focused ultrasound beam. https://app.cochat.ai/papers/10.1002/mrm.1910360513
The paper
Chung, A. H., Hynynen, K., Colucci, V., Oshio, K., Cline, H. E., & Jolesz, F. A. (1996). Optimization of spoiled gradient‐echo phase imaging for in vivo localization of a focused ultrasound beam. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910360513

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.