The DOI matches its Crossref record.
Optimization of spoiled gradient‐echo phase imaging for in vivo localization of a focused ultrasound beam
Abstract
The parameters of a spoiled gradient‐echo (SPGR) pulse sequence have been optimized for in vivo localization of a focused ultrasound beam. Temperature elevation was measured by using the proton resonance frequency shift technique, and the phase difference signal‐to‐noise ratio (SNR δ ϕ) was estimated in skeletal muscle and kidney cortex in 10 rabbits. Optimized parameters included the echo time equivalent to T*2 of the tissue, the longest repetition time possible with a 20‐s sonication, and the flip angle equivalent to the Ernst angle. Optimal SPGR phase imaging can detect a sonication beam with a peak phase difference of 0.55 radian, which corresponds to a temperature elevation of 7.3°C. The sonication beam can be localized within one voxel (0.6 × 0.6 × 5 mm 3) at power levels that are below the threshold for thermal damage of the tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Noninvasive MR Imaging–guided Focal Opening of the Blood-Brain Barrier in Rabbits
Hynynen, K., McDannold, N., Vykhodtseva, N., & Jolesz, F. A. (2001) · Radiology · doi:10.1148/radiol.2202001804 · Cited by 1,456
Self-citationMR Imaging-guided Focused Ultrasound Surgery of Fibroadenomas in the Breast: A Feasibility Study
Hynynen, K., Pomeroy, O., Smith, D. N., Huber, P. E., McDannold, N. J., Kettenbach, J., Baum, J., Singer, S., & Jolesz, F. A. (2001) · Radiology · doi:10.1148/radiology.219.1.r01ap02176 · Cited by 634
Self-citationHigh intensity focused ultrasound in clinical tumor ablation
Zhou, Y.-F. (2011) · World Journal of Clinical Oncology · doi:10.5306/wjco.v2.i1.8 · Cited by 625
MRI-Guided Focused Ultrasound Surgery
Jolesz, F. A. (2009) · Annual Review of Medicine · doi:10.1146/annurev.med.60.041707.170303 · Cited by 377
Self-citationEx vivo tissue‐type independence in proton‐resonance frequency shift MR thermometry
Peters, R. T. D., Hinks, R. S., & Henkelman, R. M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400316 · Cited by 320
Metadata
- Authors
- Chung, A. H., Hynynen, K., Colucci, V., Oshio, K., Cline, H. E., & Jolesz, F. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1996-11
- Volume
- 36
- Issue
- 5
- Pages
- 745-752
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2157277469
- Cited by
- 198
- References
- 0
- FWCI
- 14.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimization of spoiled gradient‐echo phase imaging for in vivo localization of a focused ultrasound beam. https://app.cochat.ai/papers/10.1002/mrm.1910360513
- The paper
- Chung, A. H., Hynynen, K., Colucci, V., Oshio, K., Cline, H. E., & Jolesz, F. A. (1996). Optimization of spoiled gradient‐echo phase imaging for in vivo localization of a focused ultrasound beam. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910360513
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.