Improving MR quantification of regional blood volume with intravascular T1 contrast agents: Accuracy, precision, and water exchange
Abstract
The goal of this work was to develop a comprehensive understanding of the relationship between vascular proton exchange rates and the accuracy and precision of tissue blood volume estimates using intravascular T1 contrast agents. Using computer simulations, the effects of vascular proton exchange and experimental pulse sequence parameters on measurement accuracy were quantified. T1 and signal measurements made in a rat model implanted with R3230 mammary adenocarcinoma tumors demonstrated that the theoretical findings are biologically relevant; data demonstrated that over‐simplified exchange models may result in measures of tumor, muscle, and liver blood volume fractions that depend on experimental parameters such as the vascular contrast concentration. As a solution to the measurement of blood volume in tissues with exchange that is unknown, methods that minimize exchange rate dependence were examined. Simulations that estimated both the accuracy and precision of such methods indicated that both the inversion recovery and the transverse‐spoiled gradient echo methods using a “noexchange” model provide the best trade‐off between accuracy and precision.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Self-citation
Cited by
Dynamic functional imaging of relative cerebral blood volume during rat forepaw stimulation
Mandeville, J. B., Marota, J. J. A., Kosofsky, B. E., Keltner, J. R., Weissleder, R., Rosen, B. R., & Weisskoff, R. M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390415 · Cited by 549
Self-citationYankeelov, T., & Gore, J. (2007) · Current Medical Imaging Reviews · doi:10.2174/157340507780619179 · Cited by 398
Metadata
- Authors
- Donahue, K. M., Weisskoff, R. M., Chesler, D. A., Kwong, K. K., Bogdanov, A. A., Mandeville, J. B., & Rosen, B. R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1996-12
- Volume
- 36
- Issue
- 6
- Pages
- 858-867
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2069593427
- Cited by
- 165
- References
- 1
- FWCI
- 9.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improving MR quantification of regional blood volume with intravascular T1 contrast agents: Accuracy, precision, and water exchange. https://app.cochat.ai/papers/10.1002/mrm.1910360608
- The paper
- Donahue, K. M., Weisskoff, R. M., Chesler, D. A., Kwong, K. K., Bogdanov, A. A., Mandeville, J. B., & Rosen, B. R. (1996). Improving MR quantification of regional blood volume with intravascular T1 contrast agents: Accuracy, precision, and water exchange. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910360608
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.