Unraveling diffusion constants in biological tissue by combining Carr‐Purcell‐Meiboom‐Gill imaging and pulsed field gradient NMR
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A diffusion‐weighted multi‐spin‐echo pulse sequence is presented, which allows for simultaneous measurement of T2, the fractional amplitude, and the diffusion constant of different fractions. Monte Carlo simulations demonstrate an improvement of this sequence with respect to the accuracy of diffusion constant and fractional amplitude for slow exchange. Examples are shown for a simple phantom containing two fractions. In addition, experiments on cat brain in healthy condition and following occlusion of the middle cerebral artery show that the fractional amplitude and the diffusion constant of cerebral spinal fluid and normal brain tissue can be analyzed within each pixel with acceptable accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moseley, M. E., Cohen, Y., Mintorovitch, J., Chileuitt, L., Shimizu, H., Kucharczyk, J., Wendland, M. F., & Weinstein, P. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140218 · Cited by 1,644
Cited by
Low-field permanent magnets for industrial process and quality control
Mitchell, J., Gladden, L. F., Chandrasekera, T. C., & Fordham, E. J. (2014) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2013.09.001 · Cited by 300
Three-dimensional diffusion tensor microimaging for anatomical characterization of the mouse brain
Aggarwal, M., Mori, S., Shimogori, T., Blackshaw, S., & Zhang, J. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22426 · Cited by 90
“3a, DTI images of an adult mouse brain acquired with the DW-GRASE sequence are compared to those acquired using the diffusion-weighted MSE sequence (37) that were used as the gold standard.”
MethodRelationships between tissue microstructure and the diffusion tensor in simulated skeletal muscle
Berry, D. B., Regner, B., Galinsky, V., Ward, S. R., & Frank, L. R. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26993 · Cited by 86
Jahng, G.-H., Xu, S., Weiner, M. W., Meyerhoff, D. J., Park, S., & Schuff, N. (2011) · Neuroradiology · doi:10.1007/s00234-011-0845-3 · Cited by 21
Metadata
- Authors
- van Dusschoten, D., Moonen, C. T. W., de Jager, P. A., & Van As, H.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1996-12
- Volume
- 36
- Issue
- 6
- Pages
- 907-913
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2074740524
- Cited by
- 79
- References
- 1
- FWCI
- 5.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.