Quantitative measurements of regional cerebral blood volume using MRI in rats: Effects of arterial carbon dioxide tension and mannitol
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A three‐dimensional (3D) T1‐weighted sequence was used to acquire high spatial resolution whole brain images in rats before and after the injection of an intravascular contrast agent. These T1‐weighted images were used to estimate regional cerebral blood volume (rCBV) as a percentage of blood volume in each voxel. Ventilation was manipulated to investigate the effects of altered arterial carbon dioxide tension (PaCO 2) on rCBV. In addition, different doses of a hypertonic mannitol solution were used to investigate the sensitivity of the proposed method in a serial monitoring paradigm. An rCBV of 2.40% ± 0.34% was obtained before any physiological manipulation, in good agreement with literature values using alternative techniques. Using this method, it was found that there exists a linear relationship between PaCO 2 and rCBV (R 2 = 0.77) and that rCBV increased in a dose and time dependent fashion in mannitol‐treated rats. High signal‐to‐noise was available due to the substantial increase in blood signal from the intravascular contrast agent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kety, S. S., & Schmidt, C. F. (1948) · Journal of Clinical Investigation · doi:10.1172/jci101995 · Cited by 1,827
Cited by
Osmotic Opening of the Blood–Brain Barrier: Principles, Mechanism, and Therapeutic Applications
Rapoport, S. I. (2000) · Cellular and Molecular Neurobiology · doi:10.1023/a:1007049806660 · Cited by 428
“, 1986) or magnetic resonance imaging (Lin et al., 1997) confirm that acute hypertonic exposure of brain increases cerebral blood volume.”
BackgroundMethodology of brain perfusion imaging
Barbier, E. L., Lamalle, L., & Décorps, M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1073 · Cited by 404
Tropr�s, I., Grimault, S., Vaeth, A., Grillon, E., Julien, C., Payen, J.-F., Lamalle, L., & D�corps, M. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200103)45:3<397::aid-mrm1052>3.0.co;2-3 · Cited by 333
Imaging brain deoxyglucose uptake and metabolism by glucoCEST MRI
Nasrallah, F. A., Pagès, G., Kuchel, P. W., Golay, X., & Chuang, K.-H. (2013) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2013.79 · Cited by 179
Metadata
- Authors
- Lin, W., Paczynski, R. P., Kuppusamy, K., Hsu, C. Y., & Haacke, E. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1997-09
- Volume
- 38
- Issue
- 3
- Pages
- 420-428
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2038561604
- Cited by
- 59
- References
- 1
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.