Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 161

The DOI matches its Crossref record.

Brain MRI with laser‐polarized 129xe

Swanson, Scott D., Rosen, Matthew S., Agranoff, Bernard W., Coulter, Kevin P., Welsh, Robert C., Chupp, Timothy E.·1997·Magnetic Resonance in Medicine

Abstract

The feasibility of brain MRI with laser‐polarized 129 Xe in a small animal model is demonstrated. Naturally abundant 129 Xe is polarized and introduced into the lungs of Sprague‐Dawley rats. Polarized xenon gas dissolves in the blood and is transported to the brain where it accumulates in brain tissue. Spectroscopic studies reveal a single, dominant, tissue‐phase NMR resonance in the head at 194.5 ppm relative to the gas phase resonance. Images of 129 Xe in the rat head were obtained with 98‐μl voxels by 2D chemical shift imaging and show that xenon is localized to the brain. This work establishes that nuclear polarization produced in the gas phases survives transport to the brain where it may be imaged. Increases in polarization and delivered volume of 129 Xe will allow clinical measurements of regional cerebral blood flow.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910380503

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 161

Metadata

Authors
Swanson, S. D., Rosen, M. S., Agranoff, B. W., Coulter, K. P., Welsh, R. C., & Chupp, T. E.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1997-11
Volume
38
Issue
5
Pages
695-698
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2011928146
Cited by
161
References
0
FWCI
8.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Brain MRI with laser‐polarized 129xe. https://app.cochat.ai/papers/10.1002/mrm.1910380503
The paper
Swanson, S. D., Rosen, M. S., Agranoff, B. W., Coulter, K. P., Welsh, R. C., & Chupp, T. E. (1997). Brain MRI with laser‐polarized 129xe. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910380503

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.