Improvements on an in Vivo automatic shimming method (FASTERMAP)
The DOI matches its Crossref record.
Abstract
Improvements on a localized, automatic shimming method described by Gruetter and Boesch (J. Magn. Reson. 96, 323–334 (1992)) and Gruetter (Magn. Reson. Med. 29, 804–811 (1993)) are presented. A spin‐echo sequence employing a double sech refocusing scheme is used to acquire a field map along linear projections that improves the signal‐to‐noise ratio by at least a factor of two over the stimulated echo sequence previously used. To further improve the reliability of shim adjustments, a variance‐weighted polynomial regression analysis is performed. This also extends the scope of application of this technique to global shimming. Localized 1 H spectra of human brain shimmed by this method are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dresner, A., Laurent, D., Marcucci, M., Griffin, M. E., Dufour, S., Cline, G. W., Slezak, L. A., Andersen, D. K., Hundal, R. S., Rothman, D. L., et al. (1999) · Journal of Clinical Investigation · doi:10.1172/jci5001 · Cited by 1,311
Self-citationSubtype-Specific Alterations of γ-Aminobutyric Acid and Glutamatein Patients With Major Depression
Sanacora, G., Gueorguieva, R., Epperson, C. N., Wu, Y.-T., Appel, M., Rothman, D. L., Krystal, J. H., & Mason, G. F. (2004) · Archives of General Psychiatry · doi:10.1001/archpsyc.61.7.705 · Cited by 796
Self-citationMayerson, A. B., Hundal, R. S., Dufour, S., Lebon, V., Befroy, D., Cline, G. W., Enocksson, S., Inzucchi, S. E., Shulman, G. I., & Petersen, K. F. (2002) · Diabetes · doi:10.2337/diabetes.51.3.797 · Cited by 647
“Localized shimming in the soleus was performed using FASTERMAP (28), with typical line widths of 10 Hz obtained.”
MethodSanacora, G., Mason, G. F., Rothman, D. L., Behar, K. L., Hyder, F., Petroff, O. A. C., Berman, R. M., Charney, D. S., & Krystal, J. H. (1999) · Archives of General Psychiatry · doi:10.1001/archpsyc.56.11.1043 · Cited by 627
Self-citationField mapping without reference scan using asymmetric echo-planar techniques
Gruetter, R., & Tk�?, I. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200002)43:2<319::aid-mrm22>3.0.co;2-1 · Cited by 569
Sinha, R., Dufour, S., Petersen, K. F., LeBon, V., Enoksson, S., Ma, Y.-Z., Savoye, M., Rothman, D. L., Shulman, G. I., & Caprio, S. (2002) · Diabetes · doi:10.2337/diabetes.51.4.1022 · Cited by 493
Self-citationMethodological consensus on clinical proton MRS of the brain: Review and recommendations
Wilson, M., Andronesi, O., Barker, P. B., Bartha, R., Bizzi, A., Bolan, P. J., Brindle, K. M., Choi, I., Cudalbu, C., Dydak, U., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27742 · Cited by 470
Determination of the rate of the glutamate/glutamine cycle in the human brain by in vivo 13 C NMR
Shen, J., Petersen, K. F., Behar, K. L., Brown, P., Nixon, T. W., Mason, G. F., Petroff, O. A. C., Shulman, G. I., Shulman, R. G., & Rothman, D. L. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.14.8235 · Cited by 462
Self-citationBefroy, D. E., Petersen, K. F., Dufour, S., Mason, G. F., de Graaf, R. A., Rothman, D. L., & Shulman, G. I. (2007) · Diabetes · doi:10.2337/db06-0783 · Cited by 453
Self-citationEpperson, C. N., Haga, K., Mason, G. F., Sellers, E., Gueorguieva, R., Zhang, W., Weiss, E., Rothman, D. L., & Krystal, J. H. (2002) · Archives of General Psychiatry · doi:10.1001/archpsyc.59.9.851 · Cited by 399
Self-citationLebon, V., Petersen, K. F., Cline, G. W., Shen, J., Mason, G. F., Dufour, S., Behar, K. L., Shulman, G. I., & Rothman, D. L. (2002) · The Journal of Neuroscience · doi:10.1523/jneurosci.22-05-01523.2002 · Cited by 371
“After tuning, acquisition of scout images, shimming with the FASTERMAP procedure (Shen et al., 1997), and calibration of the decoupling power, 13C NMR spectra were acquired for 10 min before and during a 160 min [2- 13C] acetate infusion (350 mol/ l sodium salt, 99% 13C enriched; Isotec,…”
Self-citationBoumezbeur, F., Petersen, K. F., Cline, G. W., Mason, G. F., Behar, K. L., Shulman, G. I., & Rothman, D. L. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.2040-10.2010 · Cited by 359
Self-citationGoddard, A. W., Mason, G. F., Almai, A., Rothman, D. L., Behar, K. L., Petroff, O. A. C., Charney, D. S., & Krystal, J. H. (2001) · Archives of General Psychiatry · doi:10.1001/archpsyc.58.6.556 · Cited by 255
“An automated shimming protocol was used to maximize B0 field uniformity in the ROI.(29) Threedimensional localization of the sensitive volume was accomplished by means of an image-selected in vivo spectroscopy sequence (comprising 8-millisecond phase-swept, hyperbolic secant inversion pulses, μ=5; bandwidth, 2000 Hz).”
MethodSelf-citationEffect of triiodothyronine on mitochondrial energy coupling in human skeletal muscle
Lebon, V., Dufour, S., Petersen, K. F., Ren, J., Jucker, B. M., Slezak, L. A., Cline, G. W., Rothman, D. L., & Shulman, G. I. (2001) · Journal of Clinical Investigation · doi:10.1172/jci200111775 · Cited by 174
Self-citation
Metadata
- Authors
- Shen, J., Rycyna, R. E., & Rothman, D. L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1997-11
- Volume
- 38
- Issue
- 5
- Pages
- 834-839
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2153816902
- Cited by
- 124
- References
- 0
- FWCI
- 5.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.