Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 192

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Elimination of eddy current artifacts in diffusion‐weighted echo‐planar images: The use of bipolar gradients

Alexander, Andrew L., Tsuruda, Jay S., Parker, Dennis L.·1997·Magnetic Resonance in Medicine

Abstract

Small gradient fields resulting from incompletely canceled eddy currents can cause geometric distortion in echo‐planar images. Although this distortion is negligible in most echo‐planar applications, the large gradient pulses used in diffusion‐weighted echo‐planar imaging can result in significant image distortion. In this report, it is shown that this distortion can be significantly reduced by the application of bipolar gradient waveforms. Both bipolar diffusion‐sensitizing gradients and an inverted gradient preparatory pulse were examined for minimizing the eddy currents responsible for these distortions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910380623

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 192

Metadata

Authors
Alexander, A. L., Tsuruda, J. S., & Parker, D. L.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1997-12
Volume
38
Issue
6
Pages
1016-1021
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1969339432
Cited by
192
References
1
FWCI
4.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Elimination of eddy current artifacts in diffusion‐weighted echo‐planar images: The use of bipolar gradients. https://app.cochat.ai/papers/10.1002/mrm.1910380623
The paper
Alexander, A. L., Tsuruda, J. S., & Parker, D. L. (1997). Elimination of eddy current artifacts in diffusion‐weighted echo‐planar images: The use of bipolar gradients. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910380623

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.