The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Elimination of eddy current artifacts in diffusion‐weighted echo‐planar images: The use of bipolar gradients
Abstract
Small gradient fields resulting from incompletely canceled eddy currents can cause geometric distortion in echo‐planar images. Although this distortion is negligible in most echo‐planar applications, the large gradient pulses used in diffusion‐weighted echo‐planar imaging can result in significant image distortion. In this report, it is shown that this distortion can be significantly reduced by the application of bipolar gradient waveforms. Both bipolar diffusion‐sensitizing gradients and an inverted gradient preparatory pulse were examined for minimizing the eddy currents responsible for these distortions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Cited by
Andersson, J. L. R., & Sotiropoulos, S. N. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.10.019 · Cited by 3,500
Diffusion tensor imaging of the brain
Alexander, A. L., Lee, J. E., Lazar, M., & Field, A. S. (2007) · Neurotherapeutics · doi:10.1016/j.nurt.2007.05.011 · Cited by 2,747
“To a certain degree, the eddy currents may be reduced using bipolar diffusion-weighting schemes.(16,17) The distortions may also be retrospectively corrected using image registration methods.”
MethodSelf-citationDiffusion‐tensor MRI: theory, experimental design and data analysis – a technical review
Basser, P. J., & Jones, D. K. (2002) · NMR in Biomedicine · doi:10.1002/nbm.783 · Cited by 1,478
The B‐matrix must be rotated when correcting for subject motion in DTI data
Leemans, A., & Jones, D. K. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21890 · Cited by 1,281
Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo
Reese, T. G., Heid, O., Weisskoff, R. M., & Wedeen, V. J. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10308 · Cited by 1,227
Diffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Imaging human connectomes at the macroscale
Craddock, R. C., Jbabdi, S., Yan, C.-G., Vogelstein, J. T., Castellanos, F. X., Di Martino, A., Kelly, C., Heberlein, K., Colcombe, S., & Milham, M. P. (2013) · Nature Methods · doi:10.1038/nmeth.2482 · Cited by 419
Diffusion Tensor MR Imaging and Fiber Tractography: Technical Considerations
Mukherjee, P., Chung, S. W., Berman, J. I., Hess, C. P., & Henry, R. G. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1052 · Cited by 390
Diffusion-Tensor MR Imaging and Tractography: Exploring Brain Microstructure and Connectivity
Nucifora, P. G. P., Verma, R., Lee, S.-K., & Melhem, E. R. (2007) · Radiology · doi:10.1148/radiol.2452060445 · Cited by 344
A Model-Based Method for Retrospective Correction of Geometric Distortions in Diffusion-Weighted EPI
Andersson, J. L. R., & Skare, S. (2002) · NeuroImage · doi:10.1006/nimg.2001.1039 · Cited by 274
Jbabdi, S., Lehman, J. F., Haber, S. N., & Behrens, T. E. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.2457-12.2013 · Cited by 213
Papadakis, N. G., Martin, K. M., Mustafa, M. H., Wilkinson, I. D., Griffiths, P. D., Huang, C. L. ‐., & Woodruff, P. W. R. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10204 · Cited by 93
Li, Z., Santhanam, P., Coles, C. D., Ellen Lynch, M., Hamann, S., Peltier, S., & Hu, X. (2013) · Psychiatry Research: Neuroimaging · doi:10.1016/j.pscychresns.2012.12.005 · Cited by 36
“This DTI sequence used a dual spin-echo technique combined with bipolar gradients (Alexander et al., 1997) which minimizes the geometric distortion induced by eddy currents.”
MethodRegional Distribution of Brain Injury After Cardiac Arrest: Clinical and Electrographic Correlates
Snider, S. B., Fischer, D., McKeown, M. E., Cohen, A. L., Schaper, F. L. W. V. J., Amorim, E., Fox, M. D., Scirica, B., Bevers, M. B., & Lee, J. W. (2022) · Neurology · doi:10.1212/wnl.0000000000013301 · Cited by 33
Cingulum bundle diffusivity and delusions of reference in first episode and chronic schizophrenia
Fitzsimmons, J., Schneiderman, J. S., Whitford, T. J., Swisher, T., Niznikiewicz, M. A., Pelavin, P. E., Terry, D. P., Mesholam-Gately, R. I., Seidman, L. J., Goldstein, J. M., et al. (2014) · Psychiatry Research: Neuroimaging · doi:10.1016/j.pscychresns.2014.08.002 · Cited by 25
Engineering clinical translation of OGSE diffusion MRI
Zhu, A., Michael, E. S., Li, H., Sprenger, T., Hua, Y., Lee, S., Yeo, D. T. B., McNab, J. A., Hennel, F., Fieremans, E., et al. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30510 · Cited by 13
Metadata
- Authors
- Alexander, A. L., Tsuruda, J. S., & Parker, D. L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1997-12
- Volume
- 38
- Issue
- 6
- Pages
- 1016-1021
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1969339432
- Cited by
- 192
- References
- 1
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.